8
360 DVS Series Direct Vent Fireplaces
10006326
Appliance
Top ......................................... 0” (0mm) to standoff
Bottom ..................................................... 0” (0mm)
Vent End ....................... 1/2” (13mm) to rear panel
Nonvent End (DVS2) ............................... 0” (0mm)
Venting
Concentric sections of DV Vent:
Top, bottom & sides ............................... 1” (25mm)
Nonconcentric sections of DV Vent:
Side and bottom .................................... 1” (25mm)
Top ......................................................... 2” (51mm)
Mantels
The height at which a combustible mantel is fitted
above the fireplace is dependent on the depth of the
mantel. This also applies to the distance between the
mantel leg (if so fitted) and the fireplace. For correct
mounting height and width, refer to Fig. 4a and 4b and
the Mantel Chart below.
The fitting of a bay window trim kit does not affect the
distances and reference points referred to in the
diagram and chart.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent
discoloration.
Clearance to Combustibles
A
B
C
D
E
V
W
X
Y
Z
Louvre Assembly
Top
Fireplace
Top of Combustion
Chamber
Bottom of Door Trim
Mantel Shelf
Mantel from Top
Ref.
or Breast Plate
Ref. of Comb. Chamber
V
10” (254mm)
A
19” (483mm)
W
8” (203mm)
B
17” (432mm)
X
6” (152mm)
C
15” (381mm)
Y
4” (102mm)
D
13” (330mm)
Z
2” (51mm)
E
11” (297mm)
Mantel Chart
CFM146
Fig. 4a Combustible mantel minimum installation.
J
F
G
H
I
Top View
Mantel Leg
CFM197
O
N
M
L
K
Front View
Side of Combustion
Chamber
Mantel
Leg
CFM170
Mantel
Mantel Leg From Side
Ref.
Leg Depth
Ref.
of Comb. Opening
F
10” (254mm)
K
11
¹⁄₂
” (292mm)
G
8” (203mm)
L
9
¹⁄₂
” (241mm)
H
6” (152mm)
M
7
¹⁄₂
” (191mm)
I
4” (102mm)
N
5
¹⁄₂
” (140mm)
J
2” (51mm)
O
3
¹⁄₂
” (89mm)
Fig. 4b Combustible mantel leg minimum installation.
A hearth is not mandatory; however, for aesthetic
purposes, we recommend installing a noncombustible
hearth that projects out 12” (305mm) or more from the
front of the fireplace.
Cold climate installation recommendation:
When installing this unit against a
noninsulated exterior wall or chase, it is
mandatory the outer walls be insulated to
conform to applicable insulation codes.
Hearth