9
83D0524
20/30/40ILDV Fireplace Insert
iNStALLAtiON
iNSeRt PLAceMeNt
•
The insert must be placed within a code-conforming
masonry fireplace or a tested and listed zero-clear-
ance (UL-127, solid fuel) fireplace. Repair any fireplace
damage prior to installation.
•
Because the insert uses a circulation blower, clean the
fireplace, smoke shelf and chimney before installing.
•
This heater may be placed in a bedroom. Please be
aware of the large amount of heat this appliance pro-
duces when determining a location.
fp1959
FIREBOX DIMS
15
56
”
(384 mm)
22
56O
”
(572 mm)
14”
(356 mm)
18”
(457 mm)
18”
(457 mm)
21”
(533 mm)
16”
(406 mm)
28”
(711 mm)
23”
(584 mm)
23
56O
”
(597 mm)
16
56O
”
(419 mm)
31”
(787 mm)
ILDV20
ILDV30
ILDV40
30iLDV
20iLDV
40iLDV
Figure 4
Minimum Openings
ZeRO-cLeARANce (MetAL) FiRePLAce
RequiReMeNtS
•
The damper and grate must be removed.
•
The smoke shelf, internal baffles, screen, refractory and
metal or glass doors may be removed (if applicable).
•
Do not remove or alter the insulation or any structured
rigid frame members (metal sides, floor, door frames,
face of the fireplace, etc.).
iMPORtANt:
Please review the following carefully.
It is normal for inserts fabricated of steel to give off some
expansion and/or contraction noises during the start up or
cool down cycle. Similar noises are found with your furnace
heat exchanger or car engine.
It is not unusual for your insert to give off some odor the
first time it is burned. This is due to the curing of the paint
and any undetected oil from the manufacturing process.
Please ensure that your room is well ventilated. OPeN
ALL WiNDOWS DuRiNG iNitiAL BuRN OFF/cuRiNG
PhASe.
Burn your insert for at least six (6) hours on "HIGH" the
first time you use it. Place the fan in the "OFF" position
during this time.
&P
ZEROCLEARANCEREQUIREMENTS
Insulation
Damper
Smoke
Shelf
Masonry Lining or Refractory
Screen
Metal or Glass Doors
Internal
Baffles
Masonry Lining or Refractory
Grate
Figure 5
Metal Fireplace Zero-Clearance Requirements
•
installer must attach red warning plate to the
inside of the firebox of fireplace with screws
supplied.
•
Do not cut any sheet metal parts of the fireplace
in which this gas fireplace insert is installed.
thiS iS StRictLy PROhiBiteD!
•
if factory-built fireplace has no gas access
hole(s) provided, drill a 1.5" (37.5 mm) or less
through lower sides or bottom of firebox. you
must plug the access hole with noncombus-
tible insulation after gas supply line has been
installed.
•
if your factory-built fireplace has air passages
on the face for zero clearance, DO NOt BLOcK
theSe PASSAGeS!
W
ARN
iNG
Содержание 20ILDVNV
Страница 36: ...36 83D0524 20 30 40ILDV Fireplace Insert...
Страница 37: ...37 83D0524 20 30 40ILDV Fireplace Insert...