background image

6

UVDC/UVDR Series Unvented Fireplaces

20007433

A

B

B

5"

A

1/2"

C

D

T226

framing dimensions

2/04

1/2” Clearance 

not Required at 

This Point

Front View

Side View

   

D

  36” Models 

39” 

38

¹⁄₄

” 

21” 

22’

  42” Models 

45” 

42

¹⁄₄

” 

22” 

32”

T226

Fig. 4

  Framing dimensions.

1"

Min.

T227

gas line install

2/04

Side Refractory

Fireplace 

Outer Wrap

1/2” Gas Pipe

Refractory Ce-

ment

Noncombustible Insula-

tion

T227

Fig. 6 

 Gas line installation.

FP1532

Vent free

nailing flanges

10/04

Nailing 

Flanges

FP1532

Fig. 5

  Secure firebox. UVDR shown.

The normal gas connection is 1/2” NPT, made at the left 
side facing the unit. If a right side connection is desired, 
the connecting pipe must be led at the rear of the fire-
place to terminate at the left hand side for connection to 
the fireplace.
Piping should be tested for leaks prior to final wall 
installation. Test for leaks using soap and water solution 
after completing the connection. DO NOT USE OPEN 
FLAME.

Step 6: Optional Procedure For Cold Climate Instal-
lations

The insulation and sealing of the enclosure around the 
fireplace is very important in cold climates. If the en-
closure is insulated and sealed properly, you can avoid 
future cold air problems. The time taken to install the 
firebox correctly is well worthwhile. The following steps 
are to stop potential cold air problems.

Insulation of the Fireplace Enclosure

When in a chase or an outside wall, the fireplace en-
closure should be insulated like any other wall of your 
home. Insulation should be installed on the outside 
wall(s) and the wall above the fireplace.

Insulate to Seal Under the Fireplace

Insulating under the fireplace is beneficial for installa-
tions on a concrete slab. The fireplace should be placed 
on insulating board. It is important that a hard, rigid 
surface be maintained, so do not use fiberglass insula-
tion for this purpose.

CAUTION:

  WHEN INSTALLING A FIREPLACE IN AN 

INSULATED ENCLOSURE, BE SURE TO MAINTAIN 
ALL MARKED AIR SPACES.

Seal Seams

Seal the seams of the fireplace where the outer wall 
meets the bottom pan and the front face. Also seal 
between the fireplace and finishing materials. Use high 
temperature caulk. Refer to Figure 7 for details of seal-
ing spaces between the fireplace and finishing materi-
als. Note the small amount of insulation installed across 
the top of the fireplace and down the sides as a backing 
for the caulk.

Step 5: Gas Piping and Connection

The gas piping must be installed in accordance with 
local codes or, in the absence of local codes, in accor-
dance with the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, latest edition.

Содержание UVDC

Страница 1: ...s having jurisdiction i e building inspectors fire marshals etc should be consulted before installation to determine the need to obtain a permit When installing the Blower Kit it is necessary to bring the power source to the fireplace before walls are enclosed Refer to Blower Kit instructions These fireboxes are approved as univer sal fireboxes and can be paired with any ANSI Z21 11 2 approved vent fr...

Страница 2: ...ices 7 Install Optional Outside Air Kit 8 Replacement Parts 10 Accessories 11 Servicing 11 Warranty 12 Table of Contents UVDC UVDR Certified To ANSI Z 21 91a 2002 Ventless Fireboxes for use with any ANSI Z21 11 2 Unvented Room Heaters Units UVDC36 GF1VC2 UVDR36 GF1VR2 UVDC42 GF1VC4 UVDR42 GF1VR4 A B C FP1531 hearth dimensions 9 04 djt Front Width Back Width Depth A B C UVDC36 35 23 16 UVDR36 889 mm...

Страница 3: ... K 8 8 9 9 N 22 22 32 32 O 21 21 22 22 Q 65 65 76 76 R 32 32 38 38 S 46 46 54 54 Fireplace Dimensions C G K I F N Gas Line Access Rough Opening Width C Rough Opening Height Rough Opening Depth S R Q S O J F D B A 6 C A H E F G 72025 ADF ADL 36 42 SPECS 2 04 Fig 1a UVDC UVDR specifications and framing dimensions 1 2 Clearance to Combustibles not Required at this Point 1 2 Clearance to Combustibles n...

Страница 4: ...llow the installation of 1 2 wall board or plywood flush with the face of the fireplace Only the header Fig 1 may rest on the standoffs on top of the firebox When the fireplace is installed over carpeting vinyl tile or any combustible material other than wood flooring it must be installed on a metal or wood panel extend ing its full width and depth Alternatively the carpet ing vinyl tile etc may be rem...

Страница 5: ...ions with Canopy 3c Clearance from Top of Fireplace Opening Clearance from Top of Fireplace Opening Mantel Combustible Projections Mantel Combustible Projections Clearance to Combustible Mantel Projections with out Canopy Combustible Projections above the fireplace must be within the area described by the dashed line when the firebox is equipped with the heat reducing canopy T225 3d Fig 3 Clearances...

Страница 6: ... time taken to install the firebox correctly is well worthwhile The following steps are to stop potential cold air problems Insulation of the Fireplace Enclosure When in a chase or an outside wall the fireplace en closure should be insulated like any other wall of your home Insulation should be installed on the outside wall s and the wall above the fireplace Insulate to Seal Under the Fireplace Insul...

Страница 7: ... the firebox opening where facing materials such as brick or stone are used on the face of the firebox It acts as a support firestop It should be attached to the face of the fireplace with screws and sealed to the fireplace with a heat resistant sealer WARNING The firebox screens must be in place be fore operating the fireplace WARNING These vent free fireplaces are not to be used with glass doors Hearth ...

Страница 8: ... collar to duct termina tion This will provide the least restriction to air flow No more than four 4 90 elbows can be used Duct run may be horizontal vertical inclined or any combina tion of these Fig 10 You are now ready to install the Outside Air Kit 1 Remove the screws retaining the outside air cover plate if provided Located on the left side of front open units on backside of multisided units D...

Страница 9: ...rain cap 7 6 00 djt Caulking Duct Ter mination Rain Cap Wall FP1061 Fig 13 Caulk and install duct termination rain cap in place Operating Precautions and Instructions Operation is automatic A slight negative pressure inside the house will open the barometric flapper valve Periodically inspect the duct termination for any block age Correct if necessary ...

Страница 10: ...Bottom Brick 73500 73500 73398 73398 6 Right Side Brick 73498 73498 73394 73394 7 Left Side Brick 75752 75752 73394 73394 8 Back Brick 73535 73535 73395 73395 9 Nailing Flange Bag of 4 w Screws 2253160 2253160 2253160 2253160 10 Panel Grille Louvre 65900 65900 65900 UVDC UVDR Series Unvented Fireplaces 5 7 8 6 4 1 2 3 7433 UVDC UVDR parts 8 04 9 10 CFM Corporation reserves the right to make change...

Страница 11: ...Blvd Mississauga Ontario Canada L5N 8A3 Servicing Repair and replacement work should only be done by a qualified service person Always shut off the gas supply and make sure the appli ance is cool before beginning any service operation Always check for gas leaks after servicing Accessories Decorative Louvre Trim Kits Polished brass finish LPB36 LPB42 4 Decorative Surrounds SPB36 SPB42 Blower Kit Louv...

Страница 12: ...pairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty whichever is longest This warranty is limited to the repair of or replacement of part s found to be defective in material or workmanship provided that such part s have been subjected to ...

Отзывы: