UVDC/UVDR Series Unvented Fireplaces

20007433

fireplace opening approximately 5” to the right 
and left from center. Two (2) screws are located 
4” down from the top on each side of the fireplace 
opening. Place the canopy, making sure the 1/4” 
hex head screws across the top of the opening 
align with the clearance holes in the canopy. Se-
cure with the four (4) previously removed screws.

WARNING: 

The firebox canopy must not be modified 

or replaced with a canopy that may be provided with 
the unvented decorative room heater.

4. 

Floor Clearances:

  No clearance is required if the 

appliance is installed per these instructions.

Installing the Firebox

This list of specific instructions will help you make cer-
tain that every installation operation is done correctly. 
Complete the installation steps in the sequence shown.
LOCAL BUILDING CODES SHOULD BE CONSULTED 
IN ALL CASES AS TO THE PARTICULAR REQUIRE-
MENTS CONCERNING THE INSTALLATION OF FAC-
TORY BUILT FIREPLACES.
Select the location for the fireplace by taking into con-
sideration the factors previously outlined in the Planning 
Ahead section of the manual.

Step 1:  Framing the Firebox

The width of the framed opening must be 39” for 36” 
models or 45” for 42” models. (Fig. 4)

8

10

12

14

16

18

20

22

24

2 4

6

8 10

8

10

12

14

16

18

20

22

2 4

6

8 10

6

T225

mantel clearance

2/04

42"

5" Min.

1"

9

¹⁄₂

"

Min.

16"

Min.

6"

24"

Min.

10"

FP604a

clearances

2/04

Combustible Per-

pendicular Wall

3a

Noncombustible 

Material

Fireplace 

Opening

FP604b

Clearances 
without Canopy

3b

Clearance to Combustible 
Mantel Projections with 
Canopy

3c

Clearance* from 

Top of Fireplace Opening (“)

Clearance* from 

Top of Fireplace Opening (“)

Mantel (Combustible) 

Projections (“)

Mantel (Combustible) 

Projections (“)

Clearance to Combustible 
Mantel Projections with-
out Canopy

*Combustible Projections above the 
fireplace must be within the area 
described by the dashed line when 
the firebox is equipped with the heat 
reducing canopy.

T225

3d

Fig. 3

  Clearances to combustibles.

The entire fireplace can be elevated above the floor 
to achieve a raised hearth effect. This can be done by 
adding a small platform to achieve the desired height.

NOTE:

  If installing a blower kit on the fireplace, the 

lower grille must be even with the floor. The wiring re-
quired for the lower blower must be installed during the 
framing stage. See blower kit installation instructions for 
wiring requirements. The nailing flanges on both sides 
were designed to allow the installation of    1/2” wall-
board or plywood flush with the face of the fireplace.

Step 2:  Install the Firebox

Install the firebox into the framed opening by setting 
it directly in front of the opening and sliding it into the 
proper position.

Step 3:  Level the Firebox

Check the level of the firebox on the top edge of the fire-
place face. Shim if necessary.

Step 4:  Secure the Firebox

Four (4) nailing flanges are supplied with the fireplace 
(found on the fireplace hearth). To level the box and 
secure it firmly in place, remove the nailing flanges from 
the hearth and install at the sides of the fireplace as 
shown in Figure 5.

NOTE:

  The nailing flanges have two (2) sets of holes 

to allow for adjustment for 1/2” or 5/8” offset of the face 
of the unit. When installing the nailing flanges, choose 
the set of holes on the nailing flange that fit with your 
application. 

Содержание UVDC

Страница 1: ...s having jurisdiction i e building inspectors fire marshals etc should be consulted before installation to determine the need to obtain a permit When installing the Blower Kit it is necessary to bring the power source to the fireplace before walls are enclosed Refer to Blower Kit instructions These fireboxes are approved as univer sal fireboxes and can be paired with any ANSI Z21 11 2 approved vent fr...

Страница 2: ...ices 7 Install Optional Outside Air Kit 8 Replacement Parts 10 Accessories 11 Servicing 11 Warranty 12 Table of Contents UVDC UVDR Certified To ANSI Z 21 91a 2002 Ventless Fireboxes for use with any ANSI Z21 11 2 Unvented Room Heaters Units UVDC36 GF1VC2 UVDR36 GF1VR2 UVDC42 GF1VC4 UVDR42 GF1VR4 A B C FP1531 hearth dimensions 9 04 djt Front Width Back Width Depth A B C UVDC36 35 23 16 UVDR36 889 mm...

Страница 3: ... K 8 8 9 9 N 22 22 32 32 O 21 21 22 22 Q 65 65 76 76 R 32 32 38 38 S 46 46 54 54 Fireplace Dimensions C G K I F N Gas Line Access Rough Opening Width C Rough Opening Height Rough Opening Depth S R Q S O J F D B A 6 C A H E F G 72025 ADF ADL 36 42 SPECS 2 04 Fig 1a UVDC UVDR specifications and framing dimensions 1 2 Clearance to Combustibles not Required at this Point 1 2 Clearance to Combustibles n...

Страница 4: ...llow the installation of 1 2 wall board or plywood flush with the face of the fireplace Only the header Fig 1 may rest on the standoffs on top of the firebox When the fireplace is installed over carpeting vinyl tile or any combustible material other than wood flooring it must be installed on a metal or wood panel extend ing its full width and depth Alternatively the carpet ing vinyl tile etc may be rem...

Страница 5: ...ions with Canopy 3c Clearance from Top of Fireplace Opening Clearance from Top of Fireplace Opening Mantel Combustible Projections Mantel Combustible Projections Clearance to Combustible Mantel Projections with out Canopy Combustible Projections above the fireplace must be within the area described by the dashed line when the firebox is equipped with the heat reducing canopy T225 3d Fig 3 Clearances...

Страница 6: ... time taken to install the firebox correctly is well worthwhile The following steps are to stop potential cold air problems Insulation of the Fireplace Enclosure When in a chase or an outside wall the fireplace en closure should be insulated like any other wall of your home Insulation should be installed on the outside wall s and the wall above the fireplace Insulate to Seal Under the Fireplace Insul...

Страница 7: ... the firebox opening where facing materials such as brick or stone are used on the face of the firebox It acts as a support firestop It should be attached to the face of the fireplace with screws and sealed to the fireplace with a heat resistant sealer WARNING The firebox screens must be in place be fore operating the fireplace WARNING These vent free fireplaces are not to be used with glass doors Hearth ...

Страница 8: ... collar to duct termina tion This will provide the least restriction to air flow No more than four 4 90 elbows can be used Duct run may be horizontal vertical inclined or any combina tion of these Fig 10 You are now ready to install the Outside Air Kit 1 Remove the screws retaining the outside air cover plate if provided Located on the left side of front open units on backside of multisided units D...

Страница 9: ...rain cap 7 6 00 djt Caulking Duct Ter mination Rain Cap Wall FP1061 Fig 13 Caulk and install duct termination rain cap in place Operating Precautions and Instructions Operation is automatic A slight negative pressure inside the house will open the barometric flapper valve Periodically inspect the duct termination for any block age Correct if necessary ...

Страница 10: ...Bottom Brick 73500 73500 73398 73398 6 Right Side Brick 73498 73498 73394 73394 7 Left Side Brick 75752 75752 73394 73394 8 Back Brick 73535 73535 73395 73395 9 Nailing Flange Bag of 4 w Screws 2253160 2253160 2253160 2253160 10 Panel Grille Louvre 65900 65900 65900 UVDC UVDR Series Unvented Fireplaces 5 7 8 6 4 1 2 3 7433 UVDC UVDR parts 8 04 9 10 CFM Corporation reserves the right to make change...

Страница 11: ...Blvd Mississauga Ontario Canada L5N 8A3 Servicing Repair and replacement work should only be done by a qualified service person Always shut off the gas supply and make sure the appli ance is cool before beginning any service operation Always check for gas leaks after servicing Accessories Decorative Louvre Trim Kits Polished brass finish LPB36 LPB42 4 Decorative Surrounds SPB36 SPB42 Blower Kit Louv...

Страница 12: ...pairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty whichever is longest This warranty is limited to the repair of or replacement of part s found to be defective in material or workmanship provided that such part s have been subjected to ...

Отзывы: