Majestic fireplaces GBR36 Series Скачать руководство пользователя страница 27

27

GBR Series B-Vent Gas Fireplace

7412955

© CFM Corporation

BASIC WARRANTY

 

CFM Corporation (hereinafter referred to collectively as the Company) 
warrants that your new Vermont Castings or Majestic Gas Fireplace/
Stove is free from manufacturing and material defects for a period of 
one year from the date of purchase, subject to the following conditions 
and limitations.

EXTENDED LIFETIME WARRANTY

 

The  heat  exchanger,  where  applicable,  and  combustion  chamber 
of every Vermont Castings or Majestic gas product is warranted for 
life against through wall perforation. All appliances equipped with an 
Insta-Flame  Ceramic  Burner  have  limited  lifetime  coverage  on  the 
ceramic burner plaque. Warrantees are made to the original owner 
subject to proof of purchase and the conditions and limitations listed 
on this Warranty Document

COMPONENT WARRANTY

CAST IRON: All external and internal cast iron parts are warranted for a 
period of three years.

 

Note

: On porcelain enamel finished external parts and accessories 

The Company offers no Warranty on chipping of enamel surfaces. 
Inspect all product prior to accepting it for any damage to the 
enamel.

 

 The salt air environment of coastal areas or a high humidity 
environment can be corrosive to the porcelain enamel finish. These 
conditions can cause rusting of the cast iron beneath the porcelain 
enamel finish, which will cause the finish to flake off.

 

Dye lot variations with replacement parts and/or accessories can 
occur and are not covered by warranty.

GLASS DOORS: Glass doors are covered for a period of one year. 
Glass doors are not warranted for breakage due to misuse or accident.  
Glass doors are not covered for discoloration or burned in stains due to 
environmental issues, or improper cleaning and maintenance.
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be 
cleaned with Lemon oil only.

 

Brass cleaners cannot be used.  Mortar 

mix and masonry cleaners may corrode the brass finish.  The Company 
will not be responsible for, nor will it warrant any brass parts which are 
damaged by external chemicals or down draft conditions.
GAS VALVES: Gas valves are covered for a period of one year
ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and 
mechanical components of the burner assembly are covered for one 
year. All steel tube burners are warranted for one year.
ACCESSORIES: Unless otherwise noted all components and CFM 
Corporation company supplied accessories are covered for a period of 
one year.

CONDITIONS AND LIMITATIONS

•  This new Vermont Castings or Majestic product must be installed by 

a competent, authorized, service contractor. A licensed technician, as 
prescribed by the local jurisdiction must perform any installation/service 
work. It must be installed and operated at all times in accordance with 
the Installation and Operating instructions furnished with the product. 
Any alteration, willful abuse, accident, or misuse of the product shall 
nullify this warranty.

•  This warranty is non-transferable, and is made to the original owner, 

provided that the purchase was made through an authorized supplier 
of the Company.

•  The customer must pay for any Authorized Dealer in-home travel fees 

or service charges for in-home repair work. It is the dealers option 
whether the repair work will be done in the customer’s home or in the 
dealer’s shop.

•  If  upon  inspection,  the  damage  is  found  to  be  the  fault  of  the 

manufacturer, repairs will be authorized at no charge to the customer 
parts and/or labor.  

•  Any  part  and/or  component  replaced  under  the  provisions  of  this 

warranty is covered for six months or the remainder of the original 
warranty, whichever is longest.

•  This warranty is limited to the repair of or replacement of part(s) found 

to be defective in material or workmanship, provided that such part(s) 
have been subjected to normal conditions of use and service, after 
said defect is confirmed by the Company’s inspection.

•  The  company  may,  at  its  discretion,  fully  discharge  all  obligations 

with respect to this warranty by refunding the wholesale price of the 
defective part(s)

•  Any installation, labor, construction, transportation, or other related 

costs/expenses  arising  from  defective  part(s),  repair,  replacement, 
or otherwise of same, will not be covered by this warranty, nor shall 
the Company assume responsibility for same. Further, the Company 
will not be responsible for any incidental, indirect, or consequential 
damages except as provided by law.

• 

SOME  STATES  DO  NOT  ALLOW  FOR  THE  EXCLUSION  OR 
LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES 
OR  LIMITATIONS  ON  HOW  LONG  AN  IMPLIED  WARRANTY 
LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR 
CIRCUMSTANCES.    THIS  WARRANTY  GIVES  YOU  SPECIFIC 
RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY FROM 
STATE TO STATE. 

•  All other warranties-expressed or implied- with respect to the product, 

its components and accessories, or any obligations/liabilities on the 
part of the Company are hereby expressly excluded.

•  The  Company  neither  assumes,  nor  authorizes  any  third  party  to 

assume on its behalf, any other liabilities with respect to the sale of 
this Vermont Castings or Majestic product

•  The  warranties  as  outlined  within  this  document  do  not  apply  to 

chimney components or other non CFM Corporation accessories used 
in conjunction with the installation of this product..

•  Damage to the unit while in transit is not covered by this warranty but 

is  subject  to  claim  against  the  common  carrier.  Contact  the  dealer 
from whom you purchased your fireplace/stove (do not operate the 
appliance as this might negate the ability to process the claim with the 
carrier).

•  The Company will not be responsible for:

a)  Down drafts or spillage caused by environmental conditions such 

as near-by trees, buildings, roof tops, hills, or mountains.

b)  Inadequate  ventilation  or  negative  air  pressure  caused  by 

mechanical systems such as furnaces, fans, clothes dryers, etc.

•  This warranty is void if:

a)  The fireplace has been operated in atmospheres contaminated by 

chlorine, fluorine, or other damaging chemicals.

b)  The  fireplace  has  been  subjected  to  prolonged  periods  of 

dampness or condensation

c)  Any  damages  to  the  fireplace,  combustion  chamber,  heat 

exchanger or other components due to water, or weather damage, 
which is the result of but not limited to, improper chimney/venting 
installation.

d)  Any alteration, willful abuse, accident, or misuse of the product 

has occurred.

IF WARRANTY SERVICE IS NEEDED…

1)  Contact your supplier.  Make sure you have your warranty, 

your sales receipt, and the model/serial number of your  
CFM Corporation product.

2)  DO NOT ATTEMPT TO DO ANY SERVICE WORK 

YOURSELF.

LIMITED LIFETIME WARRANTY 

PRODUCT COVERED BY THIS WARRANTY

All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame 
brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.

Содержание GBR36 Series

Страница 1: ...YOUR SAFETY Installation and service must be per formed by a quali ed installer service agency or the gas supplier Do not store or use gasoline or other amma ble vapors and liquids in the vicinity of...

Страница 2: ...bustibles 5 Mantels 5 Mantel Chart 5 Hearth 5 Framing Finishing 6 Final Finishing 6 Gas Speci cations 6 Gas Inlet Manifold Pressures 6 High Elevations 6 Parts Identi cation and Chase Installation 7 Ga...

Страница 3: ...any way 11 Whether the appliance is installed directly on carpeting vinyl tile or any combustible material other than wood this appli ance must be installed on a metal or wood panel extending the full...

Страница 4: ...m 140mm 40 1016mm 36 914mm 3 76mm 1 6 m m 37 953mm 13mm 1 3 7 2 m m 502mm 533mm 40 1029mm 191mm 165mm 191mm 191mm Outside Air Electrical Access Gas Line Access WFP623 GBR36 2 11 98 Rough Opening Heigh...

Страница 5: ...M L K J F G H I Mantel Leg CFM164a Mantel Leg Chart 06 22 01 sta Black Surround Face Side of Combustion Chamber CFM170 CFM164 Hearth Extension A hearth extension in front of appliance is recommend ed...

Страница 6: ...obstruct or modify the air inlet outlet grilles in any manner Finish the wall with the material of your choice Refer to Figures 2a and 2b for speci c clearances when install ing a combustible mantel o...

Страница 7: ...nient to bring the gas line in from the right side as this allows fan installation or removal without disconnecting the gas line NOTE The gas line connection can be made with 3 8 copper tubing 1 2 rig...

Страница 8: ...to a conveniently located wall receptacle box 2 Attach wire to switch and install switch into recep tacle box Attach cover plate to switch 3 Connect wiring to gas valve Refer to Figure 6 or 7 dependin...

Страница 9: ...tion excess wire completely within the EB1 Attach the cov erplate to the replace Fig 8 FP580 INSTA VENT FREE EB1 JUNCTION BOX 11 18 97 Outside Electrical Box Front Of Unit Inside Front Of Unit FP580 F...

Страница 10: ...run can be installed within the vent system using a maximum of two 45 degree elbows B FP567a Fig 11 Venting con gurations when installing 36GSKBB FP567 Fig 10 Venting con gurations Venting Runs 40 38...

Страница 11: ...hold cleaner and warm water we recommend gas replace glass cleaner After that the glass should be cleaned two or three times during each heating season depending on the circumstances present Clean gla...

Страница 12: ...s valve standing pilot only FP390 L O H I Turn counterclockwise to increase flame height Turn clockwise to lower flame height FP390 FLAME ADJUSTMENT KNOB 11 21 96 Flame Characteristics It is important...

Страница 13: ...smell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace D...

Страница 14: ...ll not push in or turn by hand do not try to repair it call a quali ed service technician Force or attempting repair may result in a re or explosion D Do not use this appliance if any part has been un...

Страница 15: ...eded All wiring connections Replace Piezo Ignitor Thermodisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple need...

Страница 16: ...ight All Wiring connections Replace thermopile Thermocouple needs a minimum 14mV Defective valve Turn to pilot meter should read greater than 100mV If not replace Thermodisk Pilot Lights with Piezo Ig...

Страница 17: ...n cable for signs of melting or buckling Take protective actions to shield cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check elect...

Страница 18: ...ner tube 7 Reinstall burner tube and retaining bracket Burner ori ce and air shutter conversion complete FC102 Air shutter 7 21 99 djt Burner Tube Retaining Screw Air Shutter Air Shutter Gap FC102 Fig...

Страница 19: ...the main burner ON check for leaks around the burner ori ce Be careful of the burner ame Tighten ori ce if necessary 5 With the main burner ON rotate the HI LO knob and verify proper burner operation...

Страница 20: ...y a quali ed technician In order to properly clean the burner and pilot assem bly turn off the gas to the unit open the glass door if used remove logs exposing the burner and pilot assembly Clean all...

Страница 21: ...the right to make changes in design materials speci cations prices and discontinue colors and products at any time without notice GBR36 Units F35A0B F34H0B Ref Description GBR36 1 Log Set Assembly 200...

Страница 22: ...Kit 53875 19 Lava Rock Package 20000376 20 Bag of Embers 7060109 21 Valve Cover 3078116 22a Electronic Valve Natural 57884 22b Electronic Valve LP 57883 23a Electronic Pilot Assembly Natural 4 Way 542...

Страница 23: ...appliance model number 2 The serial number 3 A description of the part Should you need additional information beyond what your dealer can furnish contact CFM Corporation 2695 Meadowvale Blvd Mississau...

Страница 24: ...NOTE Not for use in Canada Remote Controls Optional remote control units are available to control different functions of the appliance Model Function s Controlled RC1 ON OFF RC2 ON OFF and Temperature...

Страница 25: ...25 GBR Series B Vent Gas Fireplace 7412955...

Страница 26: ...26 GBR Series B Vent Gas Fireplace 7412955...

Страница 27: ...inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions o...

Страница 28: ...cy Ratings Model EnerGuide Ratings Fireplace Ef ciency GBR36RN 15 5 GBR36RP 15 5 GBR36EN 11 6 GBR36EP 11 6 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corp...

Отзывы: