7412955
Gas Supply ON
• Supply line hooked up
• Shutoff valve open
NO
NO
NO
NO
• Lockout has engaged. Wait
60 seconds and try again.
• For spark at electrode while
depressing Piezo - 1/8" gap to
pilot hood needed.
• All wiring connections
• Replace Piezo ignitor
• Thermodisk
• For air in lines
• Thermopile needs a minimum
325mV. Adjust pilot flame height.
• All Wiring connections
• Replace thermopile
• Thermocouple needs a minimum
14mV.
• Defective valve. Turn to pilot,
meter should read greater than
100mV. If not, replace.
• Thermodisk
Pilot Lights with
Piezo Ignitor
YES
YES
YES
YES
Pilot Stays Lit
Pilot Lights
Main Burner
System OK
START
CHECK
• Wall switch is not turned on.
Watch for grounded wires!
• Thermopile needs a minimum
325mV.
• Plugged burner orifice.
FP396
NVC-standing pilot troubleshooting