GBR Series B-Vent Gas Fireplace

7412955

GF598

nvb GAS SUPPLY INSTALL

12/4/97

Lighting and Operating Instructions

     

 

 

For Fireplaces equipped with SIT822 Gas Valve (EN or EP)

A.  This fireplace is equipped with an ignition device 

which automatically lights the pilot. 

DO NOT

 try to 

light the pilot by hand.

B. BEFORE OPERATING,

 smell all around the  

appliance area for gas. Be sure to smell next to  
the floor because some gas is heavier than the air  
and will settle on the floor.

What to do if you smell gas

• 

Do not try to light any appliance

• 

Do not operate any electrical switch.

• 

Do not use any phone in your building.

• 

Immediately call your gas supplier from a  
neighbor’s phone. 

FOR YOUR SAFETY READ THE FOLLOWING WARNINGS 

BEFORE LIGHTING THE APPLIANCE

1.  STOP! 

Read the safety information above before 

continuing.

2.  Turn off all electrical power to the appliance.
3.  This appliance is equipped with an ignition device 

which  automatically lights the pilot. 

DO NOT

 try to 

light the pilot by hand.

4.  Access the gas control by lowering the lower 

access door (louvre assembly).

Follow the gas suppliers instructions.

• 

If you cannot contact your gas supplier call 
the Fire Department

C. Use only your hand to push in or turn the gas control 

knob. Never use tools. If the knob will not push in 
or turn by hand do not try to repair it, call a qualified 
service technician. Force or attempting repair may 
result in a fire or explosion.

D. Do not use this appliance  if any part has been under 

water. Immediately call a qualified service technician 
to inspect the appliance and replace any part of the 
control system and any gas control that has been 
under water.

5.  Turn the remote switch, if used, OFF. Turn the 

wireless remote, if used, OFF.

6.  Wait five (5) minutes to clear out any gas. Then 

smell for gas, including near the floor. If you smell 
gas STOP. Follow instructions B in the safety 
warnings above. If you do not smell gas go onto the 
next step.

7.  Close the access door.
8.  Turn ON all electrical power to the appliance.
9.  Turn remote switch or wireless remote to “ON”.
10. If the appliance will not operate, follow the 

instructions TURNING OFF THE GAS TO THE  
APPLIANCE and call your service technician or  
gas supplier.

1.  Turn the remote switch to the “OFF” position.
2.  Turn OFF all electrical power to the fireplace if  

service is required.

3  Open the lower access panel.
4.  Turn the shut-off valve on the flexible gas line 

to the “OFF” position.

Warning:If you do not follow these instructions exactly, a fire or explosion 

may result causing property damage, personal injury and loss of life.

Lighting Instructions

Turning Off the Gas to the Appliance

HI

LO

FP297A

Valve in the "ON" position

1/2" Gas Supply

1/2" x 3/8" Shut-off Valve

3/8" Nipple

3/8" Union

3/8" Nipple

Содержание GBR36 Series

Страница 1: ...YOUR SAFETY Installation and service must be per formed by a quali ed installer service agency or the gas supplier Do not store or use gasoline or other amma ble vapors and liquids in the vicinity of...

Страница 2: ...bustibles 5 Mantels 5 Mantel Chart 5 Hearth 5 Framing Finishing 6 Final Finishing 6 Gas Speci cations 6 Gas Inlet Manifold Pressures 6 High Elevations 6 Parts Identi cation and Chase Installation 7 Ga...

Страница 3: ...any way 11 Whether the appliance is installed directly on carpeting vinyl tile or any combustible material other than wood this appli ance must be installed on a metal or wood panel extending the full...

Страница 4: ...m 140mm 40 1016mm 36 914mm 3 76mm 1 6 m m 37 953mm 13mm 1 3 7 2 m m 502mm 533mm 40 1029mm 191mm 165mm 191mm 191mm Outside Air Electrical Access Gas Line Access WFP623 GBR36 2 11 98 Rough Opening Heigh...

Страница 5: ...M L K J F G H I Mantel Leg CFM164a Mantel Leg Chart 06 22 01 sta Black Surround Face Side of Combustion Chamber CFM170 CFM164 Hearth Extension A hearth extension in front of appliance is recommend ed...

Страница 6: ...obstruct or modify the air inlet outlet grilles in any manner Finish the wall with the material of your choice Refer to Figures 2a and 2b for speci c clearances when install ing a combustible mantel o...

Страница 7: ...nient to bring the gas line in from the right side as this allows fan installation or removal without disconnecting the gas line NOTE The gas line connection can be made with 3 8 copper tubing 1 2 rig...

Страница 8: ...to a conveniently located wall receptacle box 2 Attach wire to switch and install switch into recep tacle box Attach cover plate to switch 3 Connect wiring to gas valve Refer to Figure 6 or 7 dependin...

Страница 9: ...tion excess wire completely within the EB1 Attach the cov erplate to the replace Fig 8 FP580 INSTA VENT FREE EB1 JUNCTION BOX 11 18 97 Outside Electrical Box Front Of Unit Inside Front Of Unit FP580 F...

Страница 10: ...run can be installed within the vent system using a maximum of two 45 degree elbows B FP567a Fig 11 Venting con gurations when installing 36GSKBB FP567 Fig 10 Venting con gurations Venting Runs 40 38...

Страница 11: ...hold cleaner and warm water we recommend gas replace glass cleaner After that the glass should be cleaned two or three times during each heating season depending on the circumstances present Clean gla...

Страница 12: ...s valve standing pilot only FP390 L O H I Turn counterclockwise to increase flame height Turn clockwise to lower flame height FP390 FLAME ADJUSTMENT KNOB 11 21 96 Flame Characteristics It is important...

Страница 13: ...smell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace D...

Страница 14: ...ll not push in or turn by hand do not try to repair it call a quali ed service technician Force or attempting repair may result in a re or explosion D Do not use this appliance if any part has been un...

Страница 15: ...eded All wiring connections Replace Piezo Ignitor Thermodisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple need...

Страница 16: ...ight All Wiring connections Replace thermopile Thermocouple needs a minimum 14mV Defective valve Turn to pilot meter should read greater than 100mV If not replace Thermodisk Pilot Lights with Piezo Ig...

Страница 17: ...n cable for signs of melting or buckling Take protective actions to shield cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check elect...

Страница 18: ...ner tube 7 Reinstall burner tube and retaining bracket Burner ori ce and air shutter conversion complete FC102 Air shutter 7 21 99 djt Burner Tube Retaining Screw Air Shutter Air Shutter Gap FC102 Fig...

Страница 19: ...the main burner ON check for leaks around the burner ori ce Be careful of the burner ame Tighten ori ce if necessary 5 With the main burner ON rotate the HI LO knob and verify proper burner operation...

Страница 20: ...y a quali ed technician In order to properly clean the burner and pilot assem bly turn off the gas to the unit open the glass door if used remove logs exposing the burner and pilot assembly Clean all...

Страница 21: ...the right to make changes in design materials speci cations prices and discontinue colors and products at any time without notice GBR36 Units F35A0B F34H0B Ref Description GBR36 1 Log Set Assembly 200...

Страница 22: ...Kit 53875 19 Lava Rock Package 20000376 20 Bag of Embers 7060109 21 Valve Cover 3078116 22a Electronic Valve Natural 57884 22b Electronic Valve LP 57883 23a Electronic Pilot Assembly Natural 4 Way 542...

Страница 23: ...appliance model number 2 The serial number 3 A description of the part Should you need additional information beyond what your dealer can furnish contact CFM Corporation 2695 Meadowvale Blvd Mississau...

Страница 24: ...NOTE Not for use in Canada Remote Controls Optional remote control units are available to control different functions of the appliance Model Function s Controlled RC1 ON OFF RC2 ON OFF and Temperature...

Страница 25: ...25 GBR Series B Vent Gas Fireplace 7412955...

Страница 26: ...26 GBR Series B Vent Gas Fireplace 7412955...

Страница 27: ...inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions o...

Страница 28: ...cy Ratings Model EnerGuide Ratings Fireplace Ef ciency GBR36RN 15 5 GBR36RP 15 5 GBR36EN 11 6 GBR36EP 11 6 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corp...

Отзывы: