10
4.0 Technical Data
© Baxi Heating UK Ltd 2011
4.1
System 24 & 28 Eco
Flue Terminal
Diameter
100mm
Dimensions
Projection
125mm
Outercase Dimensions
Casing Height
- 780mm
Overall Height Inc Flue Elbow
- 965mm
Casing Width
- 450mm
Casing Depth
- 345mm
Weights
Packaged Boiler Carton
51.1 kg (24 &28)
Installation Lift Weight
44.5 kg (24 & 28)
Central Heating Primary Circuit
Pressures
bar
Safety Discharge
3
Max Operating
2.5
Min Operating
0.5
Recommended Operating Range
1-2
Pump
Available Head
See graph below
Expansion Vessel
-
(For Central Heating only.
Integral with appliance)
bar
Min Pre-charge Pressure
0.5
(18,24)
(27)
Max Capacity of
litre
litre
CH System
125
155
Primary Water Content
of Boiler (unpressurised)
2.5
2.8
Connections
copper tails
Gas Supply
-
22mm
Central Heating Flow
-
22mm
Central Heating Return
-
22mm
Pressure Relief Discharge
-
15mm
Temperatures
C.H. Flow Temp
(adjustable)
25°C to 80°C
max
(± 5°C)
NOx Class
5
0
200
400
600
800
1000
1200
1400
0.5
1
1.5
2
2.5
3
3.5
4
Metre (wg)
Flow Rate (l/h)
Pump - Available Head (24,27)
0
5
5.5
4.5
Clearances
Above Casing
200 mm Min
300 mm Min (80/125mm flue)
Below Casing
200 mm Min
Front
450 mm Min
(For Servicing)
Front
5 mm Min
(In Operation)
L.H. Side
5 mm Min
R.H. Side
5 mm Min
(In Operation)
Heat Input CH (Net)
Max
Min
24 model
kW
26.06
7.82
28 model
kW
29.32
8.8
Heat Output CH (Non-Condensing)
Max
Min
24 model
kW
25.94
7.61
28 model
kW
28.63
8.56
Electrical Supply
230V~ 50Hz
(Appliance must be connected to an
earthed supply)
Power Consumption
150W
Electrical Protection
IPX0D (with timer)
IPX4D (without timer)
Internal Fuse Rating
F2L
Appliance Category
CAT I
2H
Inlet Pressure
(Natural Gas - G20)
mbar
20
Injector
(Natural Gas - G20)
6.0mm (24 & 28 models)
Appliance Type
C
13
C
33
C
53
Heat Output CH (Condensing)
Max
Min
24 model
kW
26.95
8.37
28 model
kW
30.20
9.42
Max Gas Rate
(Natural Gas - G20)
(After 10 mins)
24 model
m
3
/h
2.76
28 model
m
3
/h
3.10
Condensate Drain
To accept 21.5mm (
3
/
4
in) plastic waste pipe
Heat Input CH (Gross)
Max
Min
24 model
kW
28.92
8.68
28 model
kW
32.54
9.77
External Fuse Rating
3A
SAP 2005 Seasonal Efficiency for 24 models
is 91.1%
SAP 2005 Seasonal Efficiency for 28 models
is 90.2%
This value is used in the UK Government’s Standard
Assessment Procedure (SAP) for energy rating of
dwellings. The test data from which it has been
calculated has been certified by 0087.
SEDBUK Declaration
Supplied by HeatingSpares247.com