8 Installation
40
WARNING Danger of electric shock if the
ventilation units are installed within the pro-
tection zone.
The units may only be installed in the specified
protection zones in accordance with the IP de-
gree of protection. Use
PP 45
only outside pro-
tection zones 0, 1 and 2. Use
PPB 30 O
,
PPB 30
K
only outside of protection zone 0. Use
PPB 30
RC
only outside of protection zones 0 and 1.
When wiring several unit pairs/ventilation
units, always use a deep/double flush-moun-
ted box (flush-mounted box provided by cus-
tomer).
Strip wires of connection cables sufficiently.
8.7 Connecting room air controls
For RLS 45 O / RLS 45 K controls with 230 V,
observe the safety regulations → Electrical
connection 230 V.
8.7.1 Wired systems
An
RLS 45 O
or
RLS 45 K
master room air con-
trol can have a maximum of 3 further power units
and/or slave room air controls of a similar design
added to it. A maximum of 4 control units can
therefore be deployed in a
PP 45
ventilation sys-
tem.
You can only combine room air controls of the
same type (either RLS 45 O or RLS 45 K).
All other room air controls/power units are con-
nected via the RS 485 interface.
If further room air controls are connected, these
must be defined as slaves in service mode → op-
erating instructions or installation instructions.
The relevant ventilation units are connected to
the relevant room air controls/power units.
The connection of the ventilation units to an
RLS 45 O
/
RLS 45 K
generally takes place on
the terminal block of Fan1 or Fan2.
8.7.2 Radio-controlled systems
Radio controlled systems with RLS 45 K con-
trol and PP 45 EO
radio module
With this unit combination, radio units can be
paired with wired devices.
8.7.3 Connections
To install the room air control, we always recom-
mend using a deep flush-mounted box. If con-
necting more than two units, we recommend wir-
ing in a double flush-mounted box or in an addi-
tional flush-mounted box.
PPB 30 ventilation units are not suitable for
use with PP 45 LT power units.
8.7.4 Connecting RLS 45 O
RLS 45 O
room air control is used to activate
PPB 30 O units.
1. Take off frame of room air control.
2. Connect the PPBs according to the wiring dia-
The exhaust air function is only possible if a
PPB 30 O is connected (service mode setting
for unit type = PPB 30 O and number of
units = 1).
3. Insert room air control in the flush-mounted
box and screw down to flush-mounted box
with 2 screws.
4. Fit frame. Ensure that the sensor opening is
above the
PP 45 HYI
(if fitted) and that the
frame engages. Commission ventilation sys-
tem → .
8.7.5 Connecting RLS 45 K
RLS 45 K
room air control is used to activate
PPB 30 O
/
PPB 30 K
units.
Содержание PPB 30 O
Страница 3: ...Steuerungskonzept PPB 30 3 Steuerungskonzept PPB 30...
Страница 4: ...Steuerungskonzept PP 45 RC PPB 30 RC Funk 4 Steuerungskonzept PP 45 RC PPB 30 RC Funk...
Страница 29: ...PPB 30 control concept 29 PPB 30 control concept...
Страница 30: ...PP 45 RC PPB 30 RC wireless control concept 30 PP 45 RC PPB 30 RC wireless control concept...
Страница 53: ...Concept de commande PPB 30 53 Concept de commande PPB 30...
Страница 54: ...Concept de commande PP 45 RC PPB 30 RC radio 54 Concept de commande PP 45 RC PPB 30 RC radio...
Страница 95: ...Produktdatenbl tter Product data sheets Fiches techniques du produit 95 PPB 30 O...