Table of contents 

 

Fig. 1: Overview of ER EC system 

 

Standard cover for ER-A 

1  Cover – upper part 
2  Cover – lower part 
3  TimeStrip (

 Title page) 

 

ER-AK comfort cover 

1  Cover – upper part 
4  Cover – lower part with touch  

operating unit 

 

Cover with ER AH humidity control 

1  Cover – upper part 
5  Cover – lower part with touch  

operating unit 

6  Humidity sensor (rear side cover) 

 

Cover with ER AB motion detector 

7  Cover – upper part 
8  Cover – lower part with touch  

operating unit 

9  Motion detector 

 

Overview figure 

10   Accommodation mounts (3 pieces) 
11   Locking hook (3 pieces) 
12  Sealing plugs – motor board interface 

(ER-AK, ER-AH, ER-AB) 

13  Fan insert with rating plate 
14  Hole for central screw [16] 
15  Lower part of cover [2], [4], [5] or [8] 
16  Central screw, self-tapping 
17  Air filter 
18  Upper part of cover [1] or [7] 

 

 
 
 
 
 
 
 

 

Table of contents 

 Scope of delivery ...................................... 4

 

 Specialist installer qualifications ................ 4

 

 Intended use ............................................. 4

 

 Safety instructions and warnings .............. 5

 

 Operating the fan ...................................... 7

 

 System and product information ............... 7

 

6.1 Certificates of approval ...................... 7

 

6.2 ER EC covers .................................... 7

 

6.3 ER EC functions................................. 9

 

 Environmental conditions and  

   operating limits ....................................... 10

 

7.1 Regulations for operation with 

fireplaces ............................................... 10

 

 Technical data ........................................ 10

 

 Storage ................................................... 10

 

 Fan insert .............................................. 11

 

10.1 Installation of fan insert .................. 11

 

10.2 Commissioning .............................. 12

 

10.3 Removing fan insert ....................... 12

 

 Installing the cover ER-A, ER-AK,  

    ER-AH, ER-AB ...................................... 12

 

 Settings with touch operating unit   

    ER-AK, ER-AH, ER-AB ......................... 13

 

 12.1 Filter change function .................... 13

 

 12.2 Changing setting parameters ........ 13

 

 12.3 Automatic humidity function   

 ER-AH .................................................. 14

 

12.4 Motion detector function ER AB ..... 15

 

 Cleaning/maintenance .......................... 15

 

13.1 Filter change .................................. 15

 

13.2 Filter change, second room ............ 16

 

 Fault rectification ................................... 16

 

 Spare parts ........................................... 17

 

 Accessories .......................................... 17

 

 Dismantling ........................................... 17

 

 Environmentally responsible disposal ... 17

 

Acknowledgements: 

© Maico Elektroapparate-Fabrik 

GmbH. Translation of the original German operating 

instructions. Misprints, errors and technical changes 

are reserved. The brands, brand names and protected 

trade marks that are referred to in this document refer 

to their owners or their products. 

Содержание ER-A

Страница 1: ...Mounting and operating instructions ER EC covers For ER EC recess mounted exhaust air systems according to DIN 18017 3 ER A ER AK ER AH ER AB www m aico ventilatoren c om UK...

Страница 2: ...2 1...

Страница 3: ...nings 5 Operating the fan 7 System and product information 7 6 1 Certificates of approval 7 6 2 ER EC covers 7 6 3 ER EC functions 9 Environmental conditions and operating limits 10 7 1 Regulations fo...

Страница 4: ...r part of cover central screw air filter these mounting and operating instructions For accessory components chapter 16 with more detailed information and order numbers Specialist installer qualificati...

Страница 5: ...explosion Risk to health from chemicals or aggressive gases vapours Chemicals or aggressive gases vapours may harm health especially if they are distributed throughout the rooms by the fan Never use...

Страница 6: ...nted Electric components are a potential source of electric shock If the unit is open all off the supply circuits must be switched off mains fuse off secured against being accidentally switched back o...

Страница 7: ...In the event of overload blocking the fan switches off automatically Ensure sufficient supply air during operation System and product information 6 1 Certificates of approval Certificates of approval...

Страница 8: ...r change display ER AH cover Model with humidity control and time module like ER AK Barrier free product In automatic mode the fans switch on when the humidity value limit is exceeded and switches off...

Страница 9: ...base load and full load levels can be set Additional air volumes that can be set in base load 20 m h 40 m h and full load 100 m h Full load level on off via light switch or separate switch During manu...

Страница 10: ...in residential units with air ventilated fireplaces if the evaluation criteria drawn up by the responsible regional master chimney sweep are met a parallel operation of air ventilated fireplaces for l...

Страница 11: ...uction soiling if necessary 3 Check wiring diagram sticker for correctness of the ticked fan type 4 Check ease of movement of shutter When installed it must close automatically 5 Check that connection...

Страница 12: ...of the housing in parallel The degree of protection according to the rating plate is only ensured in case of proper installation fan insert correctly engaged Installing the cover ER A ER AK ER AH ER...

Страница 13: ...ime has expired the filter change LED blinks red every 5 sec To reset the filter change interval push the RESET button for 2 seconds As a confirmation the filter change LED flashes 1x briefly A new RE...

Страница 14: ...have to be specified manually If the relative humidity falls below the reference value during operation the newly established reference value is saved The lowest possible reference value is 45 relativ...

Страница 15: ...not use aggressive cleaning agents 1 Clean ER A cover only with a dry cloth 2 If the cover is very dirty remove it and clean with water 13 1 Filter change Change the air filter when ER A bar B is comp...

Страница 16: ...lt Cause measure Fan output inadequate Dirty filter Replace filter Locking hook not engaged Engage fan insert correctly Incorrect duct diameter Check duct diameter of the main duct Supply air cross se...

Страница 17: ...splay TimeStrip ZF EC replacement air filter for ER AK ER AH and ER AB article no 0093 0758 5x ZF EC replacement air filter filter class G2 Large pack of ZF EC replacement air filters for ER AK ER AH...