15. Spare parts

17 

 Spare parts 

Spare parts may only be sourced 

from and fitted by a specialist 

installer. 

Designation 

Article no. 

Exhaust socket 

0059.2046.0000 

Shutter 

E093.0608.0001 

Exhaust element 

on side 

0059.2053.0000 

Exhaust element at 

rear 

0059.2054.0000 

Cover 

upper part A/AK/AH 

0059.2047.9100 

Cover 

upper part AB 

0059.2047.9000 

In case of questions, please contact: 

Maico Elektroapparate-Fabrik GmbH 

Steinbeisstraße 20 

78056 Villingen-Schwenningen,  

Germany 

Tel. +49 7720 694 445 

Fax +49 7720 694 175 

E-mail: [email protected]

 Accessories 

Air filter 

Replacement air filters can be 

ordered at: 

www.shop.maico-ventilatoren.com 

Replacement air filter ZF EC+ 

for ER-A

, article no. 0093.0610

 

5x ZF EC+ replacement air filter

(filter class G2) and

5x filter change display

 (TimeStrip)

 Large pack of replacement air filters  

ZF EC+ for ER-A

, article no. 0093.0611

 

100x ZF EC+ replacement air filter

(filter class G2) and

100x filter change display

 (TimeStrip)

ZF EC replacement air filter 

for ER-AK, ER-AH and ER-AB, 

article no. 0093.0758

 

5x ZF EC replacement air filter

(filter class G2)

Large pack of ZF EC replacement air 

filters for ER-AK, ER-AH and ER-AB, 

article no. 0093.0759

 

100x ZF EC replacement air filter

(filter class G2)

ZRF replacement air filter for ER-ZR 

second room connection set,  

article no. 0093.0923

 

5x replacement air filters

 for internal

grille or ER-ZR second room extraction

(filter class G2)

 Dismantling 

Dismantling may only be undertaken 

by a trained electrician (

 chapter 2). 

 Environmentally responsible 

disposal 

The ventilation unit and the packaging 

contain parts that can be recycled, and 

should not end up in the domestic waste. 
Dispose of the 

packaging material 

in an 

environmentally-friendly way, in compliance 

with the regulations valid in the country where 

you are. 
Dispose of the 

air filter 

in an environment-

tally-friendly way, in compliance with the 

regulations valid in the country where you 

are. 
At the end of its service life, dispose of the 

unit

 in an environmentally-friendly way, in 

compliance with the regulations valid in the 

country where you are. 

Содержание ER-A

Страница 1: ...Mounting and operating instructions ER EC covers For ER EC recess mounted exhaust air systems according to DIN 18017 3 ER A ER AK ER AH ER AB www m aico ventilatoren c om UK...

Страница 2: ...2 1...

Страница 3: ...nings 5 Operating the fan 7 System and product information 7 6 1 Certificates of approval 7 6 2 ER EC covers 7 6 3 ER EC functions 9 Environmental conditions and operating limits 10 7 1 Regulations fo...

Страница 4: ...r part of cover central screw air filter these mounting and operating instructions For accessory components chapter 16 with more detailed information and order numbers Specialist installer qualificati...

Страница 5: ...explosion Risk to health from chemicals or aggressive gases vapours Chemicals or aggressive gases vapours may harm health especially if they are distributed throughout the rooms by the fan Never use...

Страница 6: ...nted Electric components are a potential source of electric shock If the unit is open all off the supply circuits must be switched off mains fuse off secured against being accidentally switched back o...

Страница 7: ...In the event of overload blocking the fan switches off automatically Ensure sufficient supply air during operation System and product information 6 1 Certificates of approval Certificates of approval...

Страница 8: ...r change display ER AH cover Model with humidity control and time module like ER AK Barrier free product In automatic mode the fans switch on when the humidity value limit is exceeded and switches off...

Страница 9: ...base load and full load levels can be set Additional air volumes that can be set in base load 20 m h 40 m h and full load 100 m h Full load level on off via light switch or separate switch During manu...

Страница 10: ...in residential units with air ventilated fireplaces if the evaluation criteria drawn up by the responsible regional master chimney sweep are met a parallel operation of air ventilated fireplaces for l...

Страница 11: ...uction soiling if necessary 3 Check wiring diagram sticker for correctness of the ticked fan type 4 Check ease of movement of shutter When installed it must close automatically 5 Check that connection...

Страница 12: ...of the housing in parallel The degree of protection according to the rating plate is only ensured in case of proper installation fan insert correctly engaged Installing the cover ER A ER AK ER AH ER...

Страница 13: ...ime has expired the filter change LED blinks red every 5 sec To reset the filter change interval push the RESET button for 2 seconds As a confirmation the filter change LED flashes 1x briefly A new RE...

Страница 14: ...have to be specified manually If the relative humidity falls below the reference value during operation the newly established reference value is saved The lowest possible reference value is 45 relativ...

Страница 15: ...not use aggressive cleaning agents 1 Clean ER A cover only with a dry cloth 2 If the cover is very dirty remove it and clean with water 13 1 Filter change Change the air filter when ER A bar B is comp...

Страница 16: ...lt Cause measure Fan output inadequate Dirty filter Replace filter Locking hook not engaged Engage fan insert correctly Incorrect duct diameter Check duct diameter of the main duct Supply air cross se...

Страница 17: ...splay TimeStrip ZF EC replacement air filter for ER AK ER AH and ER AB article no 0093 0758 5x ZF EC replacement air filter filter class G2 Large pack of ZF EC replacement air filters for ER AK ER AH...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Germany Service 49 7720 6940 info maico de D08 18_UK_DSW AS...

Отзывы: