9.1 ACX11 80
Feat ure
Value/ Range
Dimensions H x W x D
1016 x 580 x 840 mm
Weight
110 kg
Operating voltage
120 VAC ± 10 %
Frequency
50/60 Hz
Workplace emission sound pressure
level (as per EN ISO 11204)
< 70 dB(A)
Refrigerant
R134a
Pressure sensor
0 bar
Pressure sensor
0 bar – 34.5 bar
Pressure sensor
0 bar – 10.3 bar
Low-pressure gauge
-1 bar – 16 bar
± 1 % of final value
High-pressure gauge
-1 bar – 40 bar
±1 % of final value
Capacity of internal refrigerant bottle
10.5 kg
Maximum system pressure PS
20 bar
Pspec
18 bar
Power
900 W
Operating temperature
10°C – 50°C
Optimum R134a filling weight
for operation
4 kg – 9.5 kg
t
The ACX1180 conforms to the low voltage
directive (LVD).
9.2 Elec t rom agnet ic
c om pat ibilit y
This product complies with the standards EN 61000-6-2
and EN 61000-6-4.
1 0 . Glossar y
y
Recovery phase: The refrigerant is extracted from the
vehicle air conditioning system, cleaned and routed into
the internal bottle of the ACX1180. The refrigerant oil col-
lected in the process is drained into the used oil bottle at
the ACX1180.
y
Vacuum phase: A vacuum is generated in the vehicle air
conditioning system. Measurement of the drop in pres-
sure begins as soon as the vacuum has been generated.
y
Charging phase: A certain quantity of refrigerant is
added to the vehicle air conditioning system.