© MAHLE
16 | ACX11 80 | Com m issioning
en
4.3 ACX11 80
m
The ACX1180 is designed for 120 VAC ± 10 %, 50/60
Hz. Follow the information on ACX1180 rating plate.
1. Set the ACX1180 on a flat, vibration-proof surface.
2. Actuate the caster brake to stop ACX1180 from rolling.
3. Connect the power supply cable to the power supply.
4. Switch on the main switch.
@ The unit will prompt user to Select Language.
@ The fan is switched on.
t
The fan runs while the ACX1180 is switched on.
WE I G H T =
# #. #
L B
A U T O M A T I C
S T A R T ?
4.3.1 Set t ing
language
1. During first time setup, the unit will automatically prompt
user to select a language. After this, it will be necessary
to use
or
to get to Set up and press YES.
1. Press YES again to enter Selec t able Opt ions (or press
and hold #4 key from main menu).
2. Select language with
.
3. Store selection with YES.
4.3.2
Set t ing dat e and t im e
1. From main screen, use or to get to Set up and
press YES.
2. Use
or
to scroll to Maint enanc e Opt ions and
press YES again.
3. Press NO until Set Dat e and Tim e is displayed.
4. Alter values with
or
.
5. Move to next value with
.
6. Store entries and return with YES.
4.3.3
Act ivat ing / deac t ivat ing pr int er, buzzer
1. From main screen, use or to get to Set up and
press YES.
2. Press YES again to enter Selec t able Opt ions
3. Press YES button to scroll though various options.
4. Activate/deactivate by using or to select YES or
NO.
5. Store entries by changing selection and pressing the
YES button. Escape by pressing NO button.
4 .4 Set up
4 .4.1 Select able
Opt ions
1. From main screen, use or to get to Set up and
press YES.
2. Press YES again to enter Selec t able Opt ions.
3. Press YES button to scroll though various options.
4. Activate/deactivate by using or to select YES or
NO.
Opt ion
Descr ipt ion
Select language
Select language to be displayed on screen.
Buzzer enabled?
Audible alarm additionally sounds in the
event of error messages.
Refrig ID installed?
Optional accessory that can be purchased
and added at user convenience.
AC Cap DB installed? Optional accessory that can be enabled.
Printer installed?
Optional accessory item.
Print to flash drive?
Print results to flash drive for records.
Low voltage detect
enabled?
Only applicable to "C" version units.
Micron vacuum sen-
sor enabled?
Only applicable to "C" version units.
Password protection
enabled?
Optional setting if password protection pre-
ferred.
VIN entry enabled?
Allows technician to enter vehicles VIN
number that is being serviced.
Operator ID entry
Only applicable to "C" version units.
AC test mode ena-
bled?
Only applicable to "C" version units.
Vacuum pump oil life
test enabled?
Only applicable to "C" version units.
Refrigerant liquid
flush enabled?
Only applicable to "C" version units.
Techalert demomode
enabled?
If TechALERT is puchased, the demo can be
enabled to demonstrate use.
High pressure leak
detect enabled?
Only applicable to "C" version units.
Automatic weighing
oil injection enabled?
Only applicable to "C" version units.
Automatic weighing
oil drain enabled?
Only applicable to "C" version units.
High voltage oil flush
enabled?
Only applicable to "C" version units.
Fill cylinder enabled? Allows user to fill internal cylinder from exter-
nal refrigerant tank.
Manual oil injection
enabled?
Allows user to manually inject oil between
vacuum and charge procedure.
Содержание ACX1180