© MAHLE
M aint enance | ACX1 1 8 0 | 25
ACX118 0 | 25
| 25
en
7.5 Vac uum
pum p
7.5.1
Changing vac uum pum p oil
At t ent ion – Risk of bur ns fr om hot
sur fac es
Contact with the hot surface of the vacuum
pump will cause severe burns.
h
Allow the vacuum pump to cool down.
h
Wear protective gloves.
t
The vacuum pump oil must be changed after 10 hours of
operation. The ACX1180 will display a reminder every 10
hours of vacuum pump use.
t
Use the vacuum pump oil specified by MAHLE
(part number 360 82946 00).
1. Place a container under the drain on back side of unit.
2. Open rear service door and slide open flap to expose oil
fill port.
3. Open the drain plug and filler plug of the vacuum pump.
4. Drain all the oil.
5. Close the drain plug.
6. Pour vacuum pump oil into oil fill port until oil level is
somewhere between the min and max lines.
7. Turn on unit and start a vacuum process.
8. Check oil level.
t
Oil level is accurate when level is midway between
full and empty.
Oil change completed.