65
Dismantling procedure of the hydraulics.-
A) Dismantling procedure of the bell crank
Assembly-
1
Remove the M14 lock nut of the crank
toplink assembly.
2
Remove M14 Flange nut on the crank
toplink.
3
Remove the step bolt DC outer block of DC
Connecting link.
4
Remove the M8 bolt of pin crank top link.
5
Remove the pin crank top link.
6
Remove crank top link.
7
Remove ‘2’ bolts (M12 x 1.75) of draft
sensing mounting assembly.
8
Remove sleeve draft sensing
Hy-tec Hydraulics
Crank Toplink
Assy.
Lock Nut
Step Bolt
DC feedback
link outer
assy
Pin Crank
Toplink
Draft
Sensnsing
Mounting
Assembly
Sleeve
Retainer
Outer DC
Sensing Spring
Inner DC
Sensing Spring
Draft Sensing
Spindle
Содержание YUVRAJ 215
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 34: ......
Страница 48: ......
Страница 50: ......
Страница 53: ...53 Schematic Layout Showing Details of Control Valve Components in Neutral Position Hy tec Hydraulics...
Страница 55: ...55 Lifting Position Hy tec Hydraulics...
Страница 56: ...56 Lowering Position Hy tec Hydraulics...
Страница 58: ...58...
Страница 59: ...59...
Страница 76: ......
Страница 85: ...85...