Corrective action
: Check for pin back out at pin 34 of EMS ECU or the pin 1. Check
the 34-1 for open circuit or short to ground
Possible cause
: If the Ground wire is having problem. If the vehicle is running then
the engine will go into limp home mode and then after igniation OFF the engine
can not be started.
Corrective action
: Check for the pin back out at Pin 20 & Pin 2
Check for open circuit in Pin 20 of EMS ECU to Pin 2 of cam phase sensor
Possible cause :
If the Reference voltage wire is having problem. If the engine is running it will go
into limp home mode ( 1300 RPM) . After igniation off the engine can not be
started.
Corrective Action
: Check for pin back out, oxidation at pin 76 of EMS ECU and pin
3 at the Cam shaft sensor.
P 0341- Camshaft sensor signal error
Reason
: This error is registered when there is mismatch between the Crankshaft
signal and the camshaft signal.
Probable causes:
1. Camshaft mounting bolts loose.
2. Wrong Cam gear.
3. Wrong camshaft gear fitted.