P0192: Signal range check for rail pressure sensor below minimum limit
This error is registered when the signal is below the limit.
Effect
: Engine will shut off
Possible causes:
Voltage line is short to ground. i.e. Pin 16 & Pin 40 are short to
each other either at the pin end or the wires
Corrective action
:
Check for pin bend.
Check for the wires getting short to each other.
Defective sensor.
P 0193 –Signal range check for rail pressure sensor above the maximum limit.
Possible causes
: Open circuit in either signal or ground or voltage. or the signal is
short to ground
Hint:
If only P0193 is registered then it is either signal line is open or signal is short
to ground.
i.e. pin 40 is short to either pin 78 or either pin 40 or pin 78 is having open circuit
Effect:
Engine will switch
off.
Open circuit of either ground or voltage is combined with other errors. Refer to
the table.
Symptom/
Behavior
Codes
Possible Pin
Reason
Engine shut off
P0193,P0223
16
The ground for
the rail
pressure is also
shared
with the APP
track 2
P0193,P0222,P1253 78
The supply for
the rail
pressure is also
shared
with the APP 2.
P0192
P0193
P1190
P0194
P1191
P1192
P1193
P0087
P0088
P1253
P1254
P1256
P1257
P1258
P1259