background image

Operations  

TPS I and III for Eurosystem 

16

 

D1 1004BA1-GB03 

3.4.2 

Speedometer Test with Separate Drive 

 

The speedometer test can be conducted by using the keyboard or the remote control. If a 
remote control is not available, a second person will be needed to perform the test. 

 

Switch-on / Preparations

 

1  Switch on main switch on switch cabinet.  

2  Press ON-key. After a 30-sec. self- check, the test stand is ready for operation. 

3  Drive the rear wheel of the motorcycle onto the roller set. Use restraining straps to tie down 

the motorcycle at the sides. 

 

Conducting the test

 

 

 

Rotating test stand rollers are potentially dangerous! Risk of injury!

 

 

1  Start the motor of the motorcycle. Accelerate the motorcycle until the desired test speed has 

been reached and press the corresponding key on the remote control or keyboard for 
storage. 

 

See section 3.2.1 for the speedometer test or section 3.2.2 for the distance test. 

 

 

Switch-off

 

1  If the speed falls below 5 km/h, the tester is automatically off and the testing process is 

finished. 

2  Wait until the rollers have come to a standstill. 

3  Open the clamping device completely and exit the test stand. 

 

Содержание TPS I

Страница 1: ...D1 1004BA1 GB03 TPS I and III for Eurosystem Speedometer Tester for passenger cars transporters and motorcycles Original Operating Instructions...

Страница 2: ...any kind Subject to technical change without notice These instructions are intended for users with previous technical knowledge in the field of vehicle testing technology MANUFACTURER MAHA Maschinenba...

Страница 3: ...4 2 5 1 TPS I 4 2 5 2 TPS III Motorcycle 5 3 Operations 7 3 1 Introduction 7 3 2 Testing Procedure 7 3 2 1 Speedometer Test 8 3 2 2 Travel Distance Test 10 3 2 3 Storage of Test Values 12 3 2 4 Revie...

Страница 4: ...TPS I and III for Eurosystem IV D1 1004BA1 GB03...

Страница 5: ...that instructions that are not complied with or incompletely complied with can lead to equipment damage Notes provide additional information Safety information is provided to warn about dangerous situ...

Страница 6: ...sent potential carbon monoxide poisoning The operator owner is responsible for providing for sufficient air ventilation 1 4 Safety Regulations for Service Work Service work such as installation mainte...

Страница 7: ...only be installed and commissioned by the manufacturer s trained authorized personnel or other qualified technicians of MAHA dealers or representatives MAHA instructions must be followed when install...

Страница 8: ...d 4 t Testing speed 30 to 150 km h Weight 400 kg Tracking width 780 to 2200 mm Roller diameter 202 mm Roller length 720 mm Roller axle separation 300 mm Dimensions roller set HxWxL 220 x 580 x 2320 mm...

Страница 9: ...device 7 m Roller length 200 mm Roller circumference 635 mm Roller diameter 202 mm Optional Clamping device with side restraining rollers mechanical with crank handle pneumatic Exit support none Engi...

Страница 10: ...Description TPS I and III for Eurosystem 6 D1 1004BA1 GB03...

Страница 11: ...re the monitor must show the main menu The instruction line must show the following message New test can begin If this message does not appear press F8 NEW VEHICLE Now the test lane is ready for a veh...

Страница 12: ...of the vehicle slowly onto the roller set The vehicle must be positioned straight and centered on the roller set b Apply the parking brake 2 Preparations Secure the vehicle with tightening belts see c...

Страница 13: ...l be activated and the test stand can be exitted Exit the test stand with lift beam Before raising the lifting device the restraining straps must be removed Press F4 on the keyboard or on the remote c...

Страница 14: ...o the roller set The vehicle must be positioned straight and centered on the roller set b Apply the parking brake 2 Preparations Secure the vehicle with tightening belts see chapter 2 3 Start the test...

Страница 15: ...ress ESC to leave this screen 7 Exit the test stand without lift beam Remove the restraining straps Slowly exit the roller set in backward direction The roller blocking system will be activated and th...

Страница 16: ...1 D04 Section 4 4 Reviewing of Measurements 3 2 5 Prepare New Test Make sure that the temporary storage is empty for beginning a new test procedure and the main menu appears with the message New test...

Страница 17: ...optional 3 3 1 Equipment Overview A Switch cabinet B Emergency off button C Main switch D OFF key E ON key F Connection to manual control device G Manual control device 3 3 2 Manual Control Device Th...

Страница 18: ...ation 3 Drive the vehicle axle on which the speedometer is connected onto the roller set Use restraining straps to tie down the test vehicle at the sides Conducting the test Rotating test stand roller...

Страница 19: ...tie down the motorcycle at the sides Conducting the test Rotating test stand rollers are potentially dangerous Risk of injury 1 Start the electric motor of the speedometer tester using the potentiomet...

Страница 20: ...the roller set Use restraining straps to tie down the motorcycle at the sides Conducting the test Rotating test stand rollers are potentially dangerous Risk of injury 1 Start the motor of the motorcy...

Страница 21: ...dules should be followed Maintenance schedule 1 Lubricate drive shaft once every 200 operating hours with universal type lubricant 2 The anchoring of the roller sets as well as all fasteners and screw...

Страница 22: ...e 3 Defective transformer fuse Restore voltage to communication desk Vehicle cannot leave roller set in backward direction Free wheel roller clutch is defective Exchange free wheel roller clutch Speed...

Отзывы: