9.1.3
Constant Speed
With the operating mode
Constant Speed the dyno is regulated in such a way that the driving
speed remains constant independent from the traction (from low to full throttle) created by the
vehicle, i.e. only the the speed which was pre-set can be driven. Only the eddy current brake
effectiveness increases up to full throttle but not the speed.
1 Position the vehicle on the dyno and fix it.
2 Call up the menu LOAD SIMULATION and
then the menu point CONSTANT SPEED.
The following screen appears:
3 Enter the target value of the speed
v-target
into the entry box via the digit keys.
4 Use the button <F8 CONTINUE>.
The measurement screen appears.
The entered speed must be higher than 7 km/h.
5 Start the measurement.
6 Use the button <F6> to start or stop the
graphic recording of the measurement.