47
BA315001-en
13
Specifications
Measurement properties
Measured
variables
Measuring
range
Measurement
accuracy
Principle of
measurement
Resolution
Response
time (T90)
Gas
running
time
HC (hexane)
0 to 2 000
ppm
±4 ppm abs.
or 3% rel.
NDIR
1 ppm vol
3.5 s
2.8 s
HC (propa-
ne)
0 to 4 000
ppm
±8 ppm abs.
or 3% rel.
4 001 to
10 000 ppm
±5% rel.
10 001 to
30 000 ppm
±10% rel.
CO
0.00 to
10.00
vol. %
±0.02% abs.
or ±3% rel.
0.01 vol.
%
10.00 to
15.00
vol. %
±5% rel.
CO
2
0.00 to
16.00
vol. %
±0.3% abs. or
±3% rel.
16.01 to
20.00
vol. %
±5% rel.
O
2
0.00 to
25.00
±0.02% abs.
or 1% rel.
Electro-
chemical
0.01 vol.
%
5 s
3.3 s
Lambda
0 to 9.999
Brettschneider
calculation
0.001
Opacity
coefficient
0 to 9.99
m
−1
Extinction
measurement
0.01 m
−1
Mode A
0.05 s
Mode B
1 s
1.8 s
Opacity
0 to 99%
0.1%
Particle
mass con-
centration
1 to 1 100
mg/m
3
1 mg/m
3
Engine
temp.
0 to 150 °C
1 °C
Speed
400 to 8 000 rpm
1 rpm