6.2
Checking and Replacing the Internal Filter
The same visual check applies to the internal “shield air” filter cartridge, but this filter is
disposable and replaced as a single unit.
Remove the eight case cover retaining screws and lift off the cover. Remove the filter cartridge
from its spring clip, gently detached from the hose and replaced by a similar specification filter.
It is recommended that this check is done monthly. The following photograph shows the correct
orientation for re-fitting the disposable filter.
Fig. 9: Internal Filter Orientation
7 Disposal
If you want to dispose of the equipment, please contact your MAHA dealer or the following
address, indicating equipment type, date of purchase and serial number:
MAHA Maschinenbau Haldenwang GmbH & Co. KG
Hoyen 20
87490 Haldenwang
Germany
Phone:
+49 (0) 8374 585 0
Fax:
+49 (0) 8374 585 500
Email: [email protected]
Alternatively, you may take the equipment to a specialised waste management plant to ensure
that all components and operating liquids are properly disposed of.