85
ALTERNATE COLOR ALARM
ALARM CODE:24
Alert Alarm: Alternate Liquid Color, Component
Switch.
The Alternate Liquid Color option allows automatic switch over from
Liquid Color component 10 to liquid color component 11 when
component 10 runs out (switch over continues from 11 to 10 and so
on). This alarm is triggered by a switch over of the component
configured to switch over liquid color. For more details see Alternate
Liquid Color under Operating Options and also the LIQ parameter.
Solution: Replace Liquid Color component that has run out.
MIX MOTOR FAILURE ALARM
ALARM CODE:25
Problem: Mix Motor Failure Detected.
When enabled under Specialized Alarms and used with the Mix Motor
Failure Kit (KIT-075T), this alarm will sound when the mix motor fails to
move during intended operation.
Solution:
Check operation of Mix Motor. Check for material jam in mix
chamber, check for mix blade obstructions. Clear mix chamber and
Mix Motor operation using Manual Operations. Check thermal
overload fuse on larger blender (model 900 and higher) or Mix Motor
Fuse on Controller.
G2F PARAMETER ALARM
ALARM CODE:26
Problem: Totals have not been collected by
communications for previous cycle .
The G2F parameter is used in conjunction with the Get Totals
command. The Get Totals MLAN command can be sent with either a
command code of 16 or 17. If Get Totals used command code 16, an
internal flag in the controller is set indicating the totals have been
collected for this cycle. If the G2F Parameter is on, the blender will
stop running cycles and alarm because the flag had not been set,
indicating the totals had not been collected for the previous cycle. At
that time the "Get Status" MLAN protocol command will return an alarm
status of 26.
Solution:
Check communication status to this blender.
REMOTE RECIPE LOAD
FAILURE ALARM
ALARM CODE:35
Problem: The recipe TAG in Modbus was set to a
recipe number from 1 to 99 but the recipe does not
exist in the internal recipe database.
When a recipe number in the range from 1 to 99 is sent to Modbus
register 40107, the controller checks for the existence of a recipe with
that number in the internal recipe database. If the recipe number
exists and the controller is idle, the new recipe is loaded and register
40107 returns the new recipe number. If the recipe number does not
exist, an alarm is generated on-screen and Modbus register 40012
returns alarm code 35 = Remote Recipe Load Failure.
Solution:
Check the internal database and verify that the recipe
number exists in the database.
Содержание FLEXBUS Lite
Страница 6: ...6...
Страница 10: ...10 Blender Parts Key...
Страница 13: ...13...
Страница 100: ...100 Technical Drawings...
Страница 101: ...101...
Страница 102: ...102...
Страница 103: ...103...
Страница 104: ...104...
Страница 105: ...105...
Страница 106: ...106...
Страница 107: ...107...
Страница 108: ...108...
Страница 109: ...109...
Страница 110: ...110...
Страница 111: ...111...
Страница 112: ...112 FCA INSTALLATIONDIAGRAM...
Страница 113: ...113 WSB 4088 IO wiring diagram 120V...
Страница 114: ...114 D WSB E0001 Electrical Diagram WSB Export Single Phase...
Страница 115: ...115 D WSB E0002 Electrical Diagram WSB Export 3 Phase...
Страница 116: ...116 D WSB E0003 Electrical Diagram WSB Export 1800 3 Phase...
Страница 117: ...117 D WSB E0004 Electrical Diagram WSB Export Maxibatch...
Страница 118: ...118 D WSB P0001 Pneumatic Diagram WSB with Non Removable Hoppers...
Страница 119: ...119 D WSB P0002 Pneumatic Diagram WSB with Removable Hoppers...
Страница 120: ...120...
Страница 138: ...138 Flexbus Lite Wiring Diagrams...
Страница 139: ...139...
Страница 140: ...140 Flexbus Lite Component Map...