56
Parameters – General –Explanation
200 series settings shown as example settings
DLY 02000
CYCLE START DELAY - Delay before cycle start. (milliseconds)
Time in milliseconds that the sensor must be uncovered before cycle start. Minimum
of 02000 (ms) is recommended. With low throughput, increasing DLY may allow
better mixing if needed.
DTI 00006
WEIGH BIN DUMP TIME at end of cycle. (Seconds)
Maximum TIME allowed to determine an empty weigh reading.
STL 00500
DISPENSE SETTLE TIME. (milliseconds)
Time for dispensed material to SETTLE before weighing.
SBO 00000 SENSOR BLOW OFF
If SBO is set to a value, the Weigh Scale Blender will pulse the FCV valve by a
specified pulse length and specified delay in between pulses for the purpose of
clearing dust and particles from the face of the sensor. The pulse length is set by
the value in the 1st digit of the SBO parameter. The 1st digit for pulse width is in .1
seconds (1/10
th
second intervals). After the pulse, there will be a delay to the next
pulse based on the value set in the last 2 digits of the SBO parameter. The last 2
digits for the pulse delay are in seconds. If the SBO parameter has been activated
by entering values, the pulses will operate for a maximum of 20 times as long as the
sensor remains covered. Recommended SBO parameter setting is 10030, which
would pulse a 1/10
th
second pulse every 30 seconds.
FUL 20000
FULL BATCH TARGET WEIGHT in Grams
Change only for extremely light or heavy material. Default values are based on
average material volume. Light weight material may exceed weigh bin volume and
may require lowering FUL value. Lowering FUL decreases throughput.
MAX 30000
Maximum BIN WEIGHT - weight the software will target (grams).
FUL is the target weight that is blended each cycle. Change only for extremely fluffy
or very heavy material. MAX prevents overflowing of the weigh bin. It is reset
automatically if the FUL parameter is changed.
TH 01000
Tare Weight High Limit
TL 00500
Tare Weight Low Limit
TH and TL are upper and lower limits for tare weight.
If tare weight is below the value of TL, the ALARM sounds.
If tare weight is above the value of TH, the ALARM sounds and the weight bin
opens, attempting to empty. Increase TH if material tends to stick to the weigh bin.
Default value is model dependent. Variations in tare weigh does not affect accuracy.
PRN 00000 Percent of Regrind to be Treated as Natural
1st digit: 0 = adds, 1 = subtracts ... additive to or from the regrind.
2nd digit: Regrind component.
3rd digit: 0 = all additives. Entering a number specifies that additive component only.
Last 2 digits: Percent of Regrind. 99 = 100.
Example: 01030 - 0=add, 1=Regrind in 1, 0=all additives, 30% of regrind as natural.
3rd digit should use 1-9, A, B, C for component numbers.
Содержание FLEXBUS Lite
Страница 6: ...6...
Страница 10: ...10 Blender Parts Key...
Страница 13: ...13...
Страница 100: ...100 Technical Drawings...
Страница 101: ...101...
Страница 102: ...102...
Страница 103: ...103...
Страница 104: ...104...
Страница 105: ...105...
Страница 106: ...106...
Страница 107: ...107...
Страница 108: ...108...
Страница 109: ...109...
Страница 110: ...110...
Страница 111: ...111...
Страница 112: ...112 FCA INSTALLATIONDIAGRAM...
Страница 113: ...113 WSB 4088 IO wiring diagram 120V...
Страница 114: ...114 D WSB E0001 Electrical Diagram WSB Export Single Phase...
Страница 115: ...115 D WSB E0002 Electrical Diagram WSB Export 3 Phase...
Страница 116: ...116 D WSB E0003 Electrical Diagram WSB Export 1800 3 Phase...
Страница 117: ...117 D WSB E0004 Electrical Diagram WSB Export Maxibatch...
Страница 118: ...118 D WSB P0001 Pneumatic Diagram WSB with Non Removable Hoppers...
Страница 119: ...119 D WSB P0002 Pneumatic Diagram WSB with Removable Hoppers...
Страница 120: ...120...
Страница 138: ...138 Flexbus Lite Wiring Diagrams...
Страница 139: ...139...
Страница 140: ...140 Flexbus Lite Component Map...