7. Optional Features
7.1
analog outputs
An option to the 6510
e
is an analog output plug-in module that provides 12 channels of analog
output corresponding to volts, amps and watts. Each output is capable of, and calibrated to, ± 10
volts. The user may apply a scale factor to all outputs by selecting “Analog outputs” in the USER
MENU. See
Section 7.1.4 – Software Configuration
. Amps scaling is applied to all amp channels,
volts scaling is applied to all volt channels and watts scaling is applied to all watt channels.
7.1.1
S
PEciFicationS
Full scale output range:
±10 V max.
Number of channels:
12
output update rate (all channels) = 200 samples/sec (5 ms)
User selectable analog output scaling values are set from the front panel. Amp, volt and watt scaling
values correspond to units per analog output volts.
(units/output volt) × displayed measurement value = output volts
examples:
• +15.000 V1 with volts scaling set to 10 V/V = +1.500 V
• -100.00 V1 with volts scaling set to 100 V/V = -1.000 V
• +5.000 A1 with amps scaling set to 1 A/V = +5.000 V
• +123.0 W1 with watt scaling set to 100 W/V = +1.230 V
7.1.2
c
hannEl
a
SSignMEntS
Pin 1
Pin 13
Pin 14
Pin 25
Figure 7–1 Analog Output
Channel
input
pin number
1
phase 1, amps
1, 14
2
phase 1, volts
2, 15
3
phase 1, watts
3, 16