![Magtrol 6510e Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/magtrol/6510e/6510e_user-manual_3655228014.webp)
4
Magtrol Model 6510
e
Single-Phase Power Analyzer
Chapter 1 – Introduction
GENERAL
INFORMA
TION
6510
e
/6530
Due to the continual development of our products, we reserve the right to modify specifications without forewarning.
www.magtrol.com
magtrol inC
70 Gardenville Parkway
Buffalo, New York 14224 USA
Phone: +1 716 668 5555
Fax: +1 716 668 8705
E-mail: [email protected]
magtrol sa
Route de Montena 77
1728 Rossens / Fribourg, Switzerland
Phone: +41 (0)26 407 3000
Fax: +41 (0)26 407 3001
E-mail: [email protected]
Subsidiaries in:
Germany • France
China • India
Worldwide Network
of Sales Agents
Options and Accessories
6510e6530-US 02/14
orDering inFormation
6510
e
Single-Phase Power Analyzer
6510
e
-01
Single-Phase Power Analyzer with Analog
Output Option
6530
Three-Phase Power Analyzer
6530-01
Three-Phase Power Analyzer with Analog Output
Option
The Analog Output is a plug-in module designed specifically
for use with the 6510
e
Single-Phase Power Analyzer and 6530
Three-Phase Power Analyzer. It provides up to 12 outputs (3
for the 6510
e
, 12 for the 6530)for analog output corresponding
to volts, amps and watts. Each output is capable of, and
calibrated to, ± 10 volts. With the analog output option, the
user may apply a scale factor to all outputs. Amps scaling is
applied to all amp outputs, volts scaling is applied to all volt
outputs and watts scaling is applied to all watt outputs.
Other features include:
•
Simple Installation: Plug-in module automatically
configures power analyzer for operation
•
Frequent Output Updates: Updates every 5
milliseconds
•
Output Short Protected
•
Factory Calibrated: Calibration data/values stored on
board (EEPROM)
•
Industry Standard 25-Pin Connection
The Analog Output can be used along with a 6510
e
or 6530
Power Analyzer to output information to a strip recorder or
interface with a data acquisition system. The Analog Output
is also used as a safety feature to help trigger alarm events.
analog output option
SPECIFICATIONS
Resolution
14 bits
Temperature Coefficient
4 ppm FSR/°C (typical),
20 ppm FSR/°C (maximum)
Output Range
± 10 V maximum
Number of Outputs
3 (6510
e
)
12 (6530)
Basic Accuracy
3 least significant bits
Output Update Rate
(all channels)
200 samples/second (5 ms)
external shunts/sensors
If currents continuously reach above 20 amps, an external
sensor must be used. Magtrol offers three different types of
external shunts for use with Magtrol Models 6510
e
or 6530
High-Speed Power Analyzers.
The HA Series shunt, designed for
power cable hook-up utilizing 3/8-
16 screws, has an insulating base
and can be mounted on conductive
surfaces. The LAB Series shunt
also comes with an insulating base,
along with thumb screws for the
power leads and knurled nuts on the
sensing terminals. The FL Series is
a relatively small bus, bar-mounted
shunt with large end blocks. The
comparatively large end blocks and
short spacing aid in cooling and
allow the shunt to operate in more
extreme environments. All shunts are calibrated on equipment
with current certifications traceable to N.I.S.T.
Sensor Substitution Wiring Connection
NOTE: For the 6530 Three-Phase
Analyzer, any (or all) of the Amps
inputs may be replaced with a
shunt for any of the wiring modes.
A
N
A
L
O
G
O
U
T
P
U
T
±
V
A
±
EXT.
SYNC.
EARTH
GROUND
20VA 50/60Hz
FUSE (5x20mm)
CAUTION: DOUBLE POLE FUSING
120V UL/CSA 250mA 250V SB
240V IEC 160mA 250V T
RS-232C
GPIB/IEEE-488
MAGTROL INC.
20 A
AMPS
750 V
VOLTS
MAX.
EXT.
MAX.
1000 V
MAX.
MAX.
±10 V
SENSOR
LO
AD
MOV
CB
SHUNT
LOW
HIGH
EARTH
±
A
6510
e
Single-Phase Power Analyzer
(HA Series)
SPECIFICATIONS
HA Series LAB Series
FL Series
Rated Current 50 to 500 A 750 to 1000 A 2000 to 3000 A
Output
50 mV
Bandwidth
DC to 60 Hz
Accuracy
± 0.25%
(± 0.1% accuracy with calibration certificate is
available for an additional cost)
Operating
Temperature
For optimum accuracy, temperature of
shunt should be 30 °C to 70 °C
Available Models
Type
P/N
Amps
HA
004640
50
HA
004641
100
HA
004642
150
HA
004643
200
HA
004644
250
HA
004645
300
HA
004646
400
HA
004647
500
LAB
004648
750
LAB
004649
1000
FL
005214
2000
FL
005286
3000