Model OE-10
Installation, Operation and Maintenance
Page
7
Rev. 4/20/07
Fig 9a – Idler Side Column Ext.
Hose Routing
Fig 9b – Power Side Column Ext.
Hose Routing
23) Loosely attach power column hose and idler
column hose using the tee fitting (
in hardware
box
) Attach Power Unit Hose to power side
column extension as seen in
Fig 10a.
Connect Power unit hose to tee from
Fig 9b
and remove slack from power column hose.
Tighten loose fittings and clamps from
previous step. Serpentine any extra hose
length in overhead.
Fig 10a – Power Unit Hose
24) Thread 9/16-18 O-ring elbow (
in hardware box
)
into power unit. Attach free end of power unit
hose to elbow. See
Fig 10b.
CAUTION do
not damage rubber O-ring.
Fig 10b Power Unit Connection
25)
B
E
C
ERTAIN
A
LL
F
ITTINGS AND
C
ONNECTIONS
ARE
T
IGHT
.
I
T IS THE INSTALLERS
RESPONSIBILITY TO INSURE SYSTEM IS LEAK
-
FREE
.
Fill the Power Unit with three gallons of
clean 10wt anti-foam anti-rust hydraulic oil or
Dexron
III
ATF.
D
O
N
OT
U
SE
O
ILS
W
ITH
D
ETERGENTS
.
L
OCK
R
ELEASE
26)
Attach Mechanical Lock Release Cable
Assembly to Power Column Lock Release
Clevis using the 3/16” diameter x 1/2" long
pin and (2) “C” clip retainers,
Fig 11
.
27)
Insert threaded sleeve portion of cable
assembly in slot located on tab above locking
pawl,
Fig 11
. One jam nut should be located
on each side of tab. Position threaded sleeve
with ½” of thread below tab as indicated in
Fig 11
and tighten jam nuts.
Fig 11 –
Power Column Lock Assembly
A2151_MAGNUM.doc