background image

 
 

 
 

IMPORTANT:

  Proper installation of this stove is crucial for proper and safe operation.  Installing this 

product improperly may result in a house fire and/or personal injury.  All applicable building codes for 
your location must be followed.  In areas where building codes require additional steps to the installation 
of this product not included in this manual, the building codes will take precedent and must be followed.  
Contact your local building inspector to obtain any necessary permits or inspection guidelines before 
installing the product. 

(This appliance must be installed by a trained professional installer to assure 

proper installation and warranty of this product)  Warranty labor, parts failing due to improper 
installation and shipping will not be covered if the unit is not installed by a trained installer. 

 

9

 

DISCONNECT THE POWER CORD BEFORE SERVICING THIS STOVE!  A power 
surge

 

protector is required.

 The unit must be plugged in to a 

grounded

 120 volt 60 Hz.  

9

 

Always route the power cord away from the unit.  Do not route cord in foot traffic areas.  Do not 
pinch cord under furniture. Do not add any additional length to the power cord. 

9

 

This product requires simple periodic maintenance for proper operation and long life of the stove.  
Read and follow the maintenance schedule closely.  

Do not operate with the doors or hopper 

open. 

9

 

The MagnuM Winchester stove models are designed, approved and tested to burn 
corn/wood pellets and other Biomass fuels.

  The burning of other solid fuels such as cord wood 

in this stove is not permitted. If you are burning fuels not approved for this appliance it will void 
the warranty and no service/warranty will be allowed. 

9

 

The MagnuM models will burn high ash content fuels but will require additional 
maintenance/cleaning.  

9

 

A working smoke detector must be installed in the same room as this product. 

9

 

It is recommended that a fire extinguisher “class a-b-c” be installed close to the appliance. 

9

 

Flammable or explosive liquids such as gasoline, naphtha or engine oil must NEVER be used in or 
around this stove.  These liquids must be stored well away from this stove as the open flame in the 
burn chamber could ignite the fumes of such liquids.  

Do not burn garbage in this unit

9

 

According to HUD requirements, when installed in a mobile home, this stove must be grounded 
directly to the steel chassis of the mobile home and bolted to the floor. 

9

 

This stove is not intended for use in commercial installations but can be used. 

9

 

The moving parts of this stove are propelled by high torque electric motors.  The auger can cause 
severe injury to body parts that may get near them.  Keep all body parts away from the auger while 
the stove is plugged into an electrical outlet.  These moving parts may begin moving at any time 
while the stove is plugged in. 

9

 

This unit must be installed on a non-combustible surface.  Make sure that the unit is level. 

9

 

Do not attempt internal service to the unit when it is burning and or plugged into power. 

9

 

It is a good idea to burn the unit outside for a couple hours before installation to burn off any paint 
or oil fumes. (Most resellers pre-burn the unit before you receive them, do not worry if your unit 
looks like it has been burnt.) 

 
 
 

IMPORTANT: It is the customer’s responsibility to make sure the MagnuM appliance is installed with the 
proper make up air system and the home is checked for adequate fresh air so that the appliance does not 
become the fresh air source for the home.  It has been determined that without fresh air directly connected 
to the appliance you will have a high possibility of product failure, safety systems shutting down and 
incomplete burn causing excessive ash, soot buildup and plugging. 
 
 

SAFETY STEPS

 

Содержание Elite WIN-ACI

Страница 1: ...ressure All chimney connections elbows and fittings must be airtight Proper venting practices must be followed Consult with a venting professional 9 Ashes must be disposed of in a metal container with...

Страница 2: ...es 36 Glass Maintenance Adjustment Removal and Replacement 37 Circuit Board Functions 38 39 Setting the Draft 40 Wiring Diagram AC 41 42 Draft Slide Gate Adjustment 43 Solar Panel Connections 43 Ignit...

Страница 3: ...American Energy Systems Inc manufacturer of the MagnuM Winchester Appliances reserves the right to alter its products their specifications and or price without notice Safety tested and EPA exemption...

Страница 4: ...tove or it could be that there is a serious lacking of good quality air in the home caused by negative pressure If you have done any remodeling or if this is a newer home it is a very real possibility...

Страница 5: ...enance cleaning 9 A working smoke detector must be installed in the same room as this product 9 It is recommended that a fire extinguisher class a b c be installed close to the appliance 9 Flammable o...

Страница 6: ...proper dryness 9 Check your corn for foreign objects Your stove warranty will not cover damage done to your stove due to foreign objects in the fuel supply 9 Do not carry your corn supply over into t...

Страница 7: ...e to foreign objects in the fuel supply 9 Store your wood pellets in a dry place to prevent them from absorbing excess moisture 9 Vacuum the hopper out after every 6 7 bags to eliminate buildup of saw...

Страница 8: ...hown later in the installation manual Make sure that the shroud is with the unit when you get it The following diagram will show how to install the legs on the Leg Unit The legs are wrapped up and pac...

Страница 9: ...otection must be 3 8 minimum thickness non combustible material or equivalent extending beneath heater and to the front side rear as indicated CHIMNEY AND CONNECTOR 3 LISTED PELLET VENT ONLY NOTE REGA...

Страница 10: ...nough to ignite grass plants or shrubs located in the vicinity of the termination The grade surface must not be a lawn Distance from bottom of termination and public walkway is 7ft 2 1m minimum 9 Dist...

Страница 11: ...gth should not exceed 30 feet Diagram 11 1 Component Equivalent Length Equivalent Pipe Length Horizontal Straight Pipe Actual Length in ft x 1 0 Horizontal Pipe 1 x 2 1 3 ft Vertical Straight Pipe Act...

Страница 12: ...epending on length of run elbows and configuration you will have to increase the size of the fresh air intake Typically you would increase from 3 to 4 over 10 of run or more than 2 elbows 4 Only non c...

Страница 13: ...er local building codes fire codes and the safety listing tag on the inside hopper lid An outside air source must be connected to the stove and can be brought in through the sidewall or vented crawl s...

Страница 14: ...E FOLLOWING REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME 1 Stove must be permanently bolted to the floor 2 Stove must have permanent outside air source 3 Stove must be permanently elec...

Страница 15: ...s per the pellet vent manufacturer s instructions Connect the pipe and lock the joints as directed by the pellet vent manufacturer and secure the vent pipe to the flue collar on the back of the stove...

Страница 16: ...te The pipe lengths shown are for reference only Your actual pipe length requirements may differ SINGLE WALL PIPE SHALL NOT BE USED FOR ANY INSTALLATION HORIZONTAL INSTALLATION SHALL BE A MAXIMUM OF 5...

Страница 17: ...s and presence of all necessary parts including a chimney cap prior to making the connection 3 This stove may be connected to an existing ceiling mounted factory built chimney with a diameter of 4 6 o...

Страница 18: ...s ash buildup premature failure of exhaust system staining of the house siding and serious creosote buildup This installation should not be used in a cold climate area Storm Collar Note This type of i...

Страница 19: ...er from the upper position to the lower position see details below 7 Connect the thermostat wires to the two terminals on the back of the control panel When the room temperature drops below the thermo...

Страница 20: ...20 MAGNUM WIN INSERT INSTALLATION...

Страница 21: ...21 WIN INSERT INSTALLATION cont Siding Use only rigid Pellet Vent pipe Framing Chimney cap Storm Collar Seal Plate 3 75mm Minimum Clearance Around vent 6 150mm min 16 375mm minimum 6 150mm minimum...

Страница 22: ...st use some type of support bolt to hold and level the unit not provided For a raised Hearth you can have a decorative skirting made by your installer to finish off the front of the unit The skirting...

Страница 23: ...resh air intake either out the back of the fireplace cavity or down and out to an outside air source Running the fresh air up and out the top of the chimney can cause excessive draft issues Your insta...

Страница 24: ...24...

Страница 25: ...25 Fireplace Insert Shroud Installation Diagram...

Страница 26: ...26 Thermostat wire connection Low voltage thermostat Molex Plug 24 volt thermostat hookup...

Страница 27: ...he control center Please NOTE Power on light glows amber when on Heat level indictor LED red per heat level setting Heat level up adj button Exhaust Draft Blower trim adjustment button ON OFF control...

Страница 28: ...pot When fuel begins to drop regularly release auger button the auger is primed NOTE The viewing door ash pan door and hopper door must be closed and or latched during operation or vacuum will not be...

Страница 29: ...l Unplugging the unit will prevent this from happening OPERATING INSTRUCTIONS Without using system igniter NOTE Each time the stove is started the firepot should be checked for debris and clear air ho...

Страница 30: ...tage or interruption lasting longer than 5 seconds the On Off button must be pushed to re engage the auger If needed re light the unit NOTE If the fire is burning too fast and the fuel is being burned...

Страница 31: ...ired burn rate by moving the control center to the desired operating position B Select the most efficient burn by adjusting the air damper control rod An air damper closed too much will produce a lazy...

Страница 32: ...ASH TO ESCAPE INTO THE ROOM AIR HOWEVER VACUUMING Use an approved Ash vacuum system IS RECOMMENDED OCCASIONALLY TO AID IN SEASONAL CLEANING AND KEEP THE UNIT FREE OF EXCESS ASH DISCARD THE VACUUM BAG...

Страница 33: ...ason dust and ash may collect on the blades of the combustion blower Periodically they should be inspected vacuumed and clean The combustion blower is accessed by opening the stove s right side panel...

Страница 34: ...they should be inspected and vacuumed clean The combustion blower is accessed by removing the inspection caps or the exhaust manifold cover See figure below Never operate the stove without the inspec...

Страница 35: ...they will be ignited in the chimney and produce damage to the chimney or even possibly destroy the home Clean the chimney as often as needed and never go more than one 1 year without a flue cleaning...

Страница 36: ...nit overheats it will shut itself down safely The unit may not be restarted until it has cooled and the reset button is depressed See Thermodisk location section If the auger does not turn after clean...

Страница 37: ...glass is not sitting on top of any obstructions The glass will break when tightening the screws if the glass is on the gasket Hold the glass toward the top of the door glass channel when tightening C...

Страница 38: ...tton allows for a low high fuel setting fine tune adjustment on the all 5 settings When pushing the auger trim button select either the heat level up button or heat level down button depending on the...

Страница 39: ...the damper is on the back of the unit you trying it up will increase draft and turning to a 90 deg position will decrease A little movement of the knob goes a long way to changing the flame It may tak...

Страница 40: ...40 AC MODEL WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT...

Страница 41: ...w degrees at a time until the proper operation of the unit is achieved NOTE This adjustment must be made by a qualified MagnuM Service Technician When rotating the slide gate be careful not to damage...

Страница 42: ...installing the new igniter hand tighten the igniter and then apply slight pressure to secure the threads Do not over tighten the igniter assembly If you over tighten the igniter assembly it may ruin...

Страница 43: ...ates 9 Change to a better grade of fuel if necessary 9 Check that damper control knob is adjusted properly Pull out to increase fire burn 9 Push ash cleanout slides in 9 Check gasket seal around the d...

Страница 44: ...witch or relay 9 Check contents of the hopper Add fuel if necessary 9 Check all operations fuses re set manual high limit thermodisk 9 Clean out auger system 9 Have your MagnuM reseller diagnose the p...

Страница 45: ...the home 9 Clean the glass when the unit is not running 9 Seal any leaks in the exhaust system with RTV high temperature silicone sealer 9 Use approved ash vacuum 9 Correct negative pressure situation...

Страница 46: ...fuel Lack of clean combustion air Dirty or plugged stove or venting Poor exhaust vent configuration Negative pressure present in the home Exhaust fan motor going out Use combustion enhancement system...

Страница 47: ...RP2098 MagnuM Baby Countryside WIN Arched Glass w gasket R 131 Glass Gasket 5 16 separate per foot R 133 Door Gasket 3 8 separate per foot MF3626 Door Handle Assembly RP2070 WIN Gold Door complete doo...

Страница 48: ...aims submitted verbally or without the required information and documentation Before exercising this warranty an AES representative the place where the product was purchased or AES approved person mus...

Страница 49: ...49 SERVICE RECORD DATE SERVICE OR CLEANING PERFORMED This record must be sent in when any warranty claims are made...

Отзывы: