38
Basic Circuit Board Functions (expanded)/Diagnostics Operation
The ON/OFF button initiates the start of the circuit board and the shut down of the
board. Pushing the ON/OFF button momentarily will engage the start up sequence.
The ON/OFF button also is used to re-set the board when the vacuum switch or proof
of fire switch is tripped. Pushing the ON/OFF button until the board re-sets (usually
6-7 seconds) will re-establish the system and the fire will continue unless there is a
failure in the electrical components.
When you push the ON/OFF button to start the unit, power light will be on and the
start up sequence will take approx. 12-15 min. During the start up sequence, the fuel
level setting will be over ridden and the unit will feed at the pre-set fuel rate setting.
After the start up sequence has been established (approx. 12-15 min.) the unit will
run at whatever fuel level setting you selected. The number #2 or #3 heat level
setting is recommended for the 1
st
30-45 minutes.
The auger light will flash when the auger is running. On the wood setting the auger
will start right away. If on the corn setting there is a (1) minute delay prior to
starting. You can hold the auger button down to override the system and manually
prime the auger.
The room fan button will override the # 1 heat level setting fan speed and go to high
speed. This will not change the fan speed on the #2 - #5 heat level settings.
The auger trim button allows for a low/high fuel setting fine tune adjustment on the
all 5 settings. When pushing the auger trim button select either the heat level up button or heat level down button
depending on the fine tune requirements.
The draft trim allows for a low/high setting fan speed and go to a lower or higher
setting depending on requirements. When pushing the draft trim button select
either the heat level up button or the heat level down button to fine tune fan
speed.
The heat level setting button is a manual heat adjustment. Pushing the heat level
setting button will advance the heat settings one level each time that it is pushed.
The LED light will show which heat level setting the unit is on. At start up,
regardless of where the heat level setting button is set, the unit will feed on the
pre-set heat level setting. Once the start up sequence has been established, the
fuel feed rate setting will run at whatever fuel level setting you selected.
During a short power outage, the board will detect if the proof of fire switch is
engaged. If it is still engaged (closed) the unit will auto re-start.
Shutdown
To shut the unit down, simply press the On/Off button. The room fan and
exhaust blower will continue to operate until the low limit/cool down
sensor tells it that the fire is out. At that point the exhaust fan will
continue to run for an additional 15 minutes to make sure there is no
exhaust in stove.
Before starting the MagnuM Biomass unit again, it is important to remember to clean out the firepot,
empty the ashes, clean out the heat exchangers, vacuum out the hopper if needed and fill the hopper
with fuel.
Содержание Elite WIN-ACI
Страница 20: ...20 MAGNUM WIN INSERT INSTALLATION...
Страница 24: ...24...
Страница 25: ...25 Fireplace Insert Shroud Installation Diagram...
Страница 26: ...26 Thermostat wire connection Low voltage thermostat Molex Plug 24 volt thermostat hookup...
Страница 40: ...40 AC MODEL WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT...