15.
AC output connection -
AC knockout (output) for hardwiring.
16.
AC input connection
-
AC knockout (input) for hardwiring.
17.
DC Ground terminal -
this connection is used to tie the exposed
chassis of the inverter to the DC grounding system. This terminal ac-
cepts CU/AL conductors from #14 AWG to #6 AWG.
Battery Temperature Sensor (Battery Charger Models Only)
A plug-in external Battery Temperature Sensor (BTS) is provided
for units with the battery charger feature. When installed, the BTS
automatically adjusts the battery chargers BULK, ABSORB, and
FLOAT voltage set-points based on temperature for better charging
performance and longer battery life. If the temperature sensor is NOT
installed and the batteries are subjected to large temperature changes,
the battery life may be shortened.
Figure 4, Left Side Features
FRONT VIEW
SIDE VIEW
~2"
~1"
~½”
0.375" diameter
Cable
~¾”
16
17
15
5