Page 31
©
2012 Magnum Energy, Inc.
Installation
Figure 2-14, AC Wiring for Dual In – Single Out Confi gurations
MMPxxx-30D Enclosure
(with Magnum Inverter)
Main Panel
(Utility/Generator 30A per leg)
ON
OFF
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
ON
OF
F
DUAL IN / SINGLE OUT
AC Wiring
HOT 1
IN
AC IN
(from grid/gen)
GR
OUND
AC IN
(to inverter
AC Input)
AC OUT
(from inverter
AC Output)
.
AC OUT
(to AC loads)
HO
T 2
O
U
T
NE
UT O
U
T
NEUT IN
HOT 1
IN
HOT 2
IN
HO
T
2
IN
NEUT IN
NE
UT
O
U
T
HO
T 2
OUT
Sub-Panel and Outlets
(Inverter AC Loads)
ON
OFF
120
VAC
120
VAC
ON
OF
F
ON
OF
F
If the main panel
has a neutral to
ground connection,
unscrew this
‘Ground to Neutral’
wire connection
from the GROUND
busbar.
**
This will
isolate the neutral
from ground to
prevent multiple
neutral to ground
bonds.
**Note:
This
Ground to Neutral
wire has already
been removed in
the inverter diagram
to the right.
Содержание Mini Magnum Panel