© 2011 Magnum Energy, Inc.
7
4.0 Using LED Indicators to Determine MagWeb’s Status
4.0 Using the LED Indicators to Determine the
MagWeb’s Status
There is a bi-color LED indicator on top of the MagWeb device (next to the
Ethernet port) to indicate the MagWeb’s status. When the device is fi rst
powered up, the LED blinks red and green while going through a self-test.
Once the self-test is complete, use the table below and the LED indicator on
your device to determine the MagWeb’s operating status.
If the MagWeb device does not function correctly, use Table 4-1 to help fi nd
a solution.
4.1 MagWeb Device LED Status
Table 4-1, MagWeb Device’s LED Indicator Guide
LED Status
Meaning
OFF
Ensure the inverter has power and the cables
are correctly seated into the MagWeb device.
Red
ON,
Green
ON,
Red
ON,
Green
ON
Power-up sequence (1-second interval
between each color). The MagWeb device is
performing a self-test – this occurs when fi rst
connected to power.
Green
ON
Normal operation: the MagWeb device is
correctly transmitting and receiving with
network devices.
Green
BLINKING
Remote not connected, or device is not able to
communicate with remote display.
Ensure the correct cable is connected between
the MagWeb and the remote. If the remote/
router display is off, refer to the remote/router
owner’s manual for troubleshooting.
Red
ON
The power-up sequence failed. Contact
Magnum Energy.
Red
BLINKING
No communication, or an unrecognizable
communication on the network.
Check the remote cable; ensure it is connect-
ed correctly.
Important:
Ensure the RJ11 connectors are
pushed into the correct port; you should feel/