Disclaimer of Liability

The use of this manual and the conditions or methods of installation, opera-

tion, use, and maintenance of the ME-MW-E (MagWeb) is beyond the control of 

Magnum Energy, Inc. Therefore, this company assumes no responsibility and 

expressly disclaims any liability for loss, damage or expense whether direct, 

indirect, consequential, or incidental that may arise out of or be in anyway 

connected with such installation, operation, use, or maintenance.
Due to continuous improvements and product updates, the images shown in 

this manual may not exactly match the unit purchased.

Restrictions on Use

The ME-MW-E may only be used in life-support devices or systems with the 

express written approval of Magnum Energy. Failure of the ME-MW-E can 

reasonably be expected to cause the failure of that life-support device or 

system, or to affect the safety or effectiveness of that device or system. If 

the ME-MW-E fails, it is reasonable to assume that the health of the user or 

other persons may be endangered.

IMPORTANT PRODUCT SAFETY INSTRUCTIONS

This manual contains important safety instructions that must be followed 

during the installation and operation of this product. Read all instructions 

and safety information contained in this manual before installing or using 

this product.

•  All electrical work must be performed in accordance with local, state, 

and federal electrical codes.

•  This product is designed for indoor/compartment installation. It must 

not be exposed to rain, snow, moisture, or liquids of any type.

•  Use insulated tools to reduce the chance of electrical shock or acciden-

tal short circuits.

•  Remove all jewelry such as rings, watches, bracelets, etc., when installing 

or performing maintenance on the ME-MW-E and the inverter system.

•  Always disconnect the batteries or energy source prior to installing or 

performing maintenance on the ME-MW-E and the inverter system. Live 

power may be present at more than one point since an inverter utilizes 

both batteries and AC. Turning off the inverter may not reduce this 

risk. As long as AC power is connected, it will pass through the inverter 

regardless of the power switch on the inverter or the ON/OFF INVERTER 

pushbutton on the remote.

Safety Symbols

To reduce the risk of electrical shock, fi re, or other safety hazard, the follow-

ing safety symbols have been placed throughout this manual to indicate 

dangerous and important safety instructions.

WARNING:

 This symbol indicates that failure to take a speci-

fi ed action could result in physical harm to the user.

CAUTION:

 This symbol indicates that failure to take a speci-

fi ed action could result in damage to the equipment.

Info:

 This symbol indicates information that emphasizes or 

supplements important points of the main text.

Содержание MagWeb Wired Ethernet

Страница 1: ...Owner s Manual ME MW E MagWeb Wired Ethernet ...

Страница 2: ... installing or using this product All electrical work must be performed in accordance with local state and federal electrical codes This product is designed for indoor compartment installation It must not be exposed to rain snow moisture or liquids of any type Use insulated tools to reduce the chance of electrical shock or acciden tal short circuits Remove all jewelry such as rings watches bracele...

Страница 3: ...p the MagWeb Device 4 2 2 1 Connecting MagWeb to a Local Area Network and the Internet 6 2 2 2 Connecting MagWeb to a Single Inverter 6 2 2 3 Connecting MagWeb to a Single Inverter and Remote Control 6 2 3 Configuring the Local Area Network 6 2 4 Registering on data magnumenergy com 6 3 0 Using data magnumenergy com 6 4 0 Using LED Indicators to Determine MagWeb s Status 7 4 1 MagWeb Device LED St...

Страница 4: ...ustration of MagWeb Device 1 Figure 2 1 MagWeb System Diagram 3 Figure 2 2 MagWeb Dimensions 5 Figure 4 1 MagWeb Wired Ethernet LED Diagram 9 List of Tables Table 4 1 MagWeb Device s LED Indicator Guide 7 Table 4 2 Functions of LEDs Below the Ethernet Port 8 ...

Страница 5: ... monitor and the automatic generator start module Using your always on internet connection the MagWeb system makes live and historical conditions available via a web browser and our data magnumenergy com service The MagWeb system uses the sensors and controllers already built into Magnum products There are no external sensors to install configure or calibrate Figure 1 1 Illustration of MagWeb Devi...

Страница 6: ...n and out Inverter stack mode AC frequency Status including fault s Invert and Charge LEDs DC volts Battery temperature DC amps Transformer temperature AC volts out FET temperature 1 2 2 Inverter Remote Compatible with all versions of Magnum s Standard Remote Control ME RC50 Advanced Remote Control ME ARC50 and Router ME RTR For PAE systems using the Magnum router the current MagWeb firmware will ...

Страница 7: ... be performed by qualified person nel such as a licensed or certified electrician It is the install er s responsibility to determine which safety codes apply and to ensure that all applicable installation requirements are followed Applicable installation codes vary depending on the specific location and application Info The MagWeb is plugged directly into a wired Ethernet connection using the supp...

Страница 8: ...tion that is dry and away from extreme temperatures Use the two supplied 8 x 3 4 screws to securely affix the module Allow ample room to view the MagWeb device s LED and to access all connectors CAUTION Do not mount the MagWeb device in a closed battery compartment or in an area where water or any other liquid can enter the device and cause shorting or corrosion Failure due to improper mounting is...

Страница 9: ...MagWeb Dimensions Side view Top view 0 9 in 23 mm 3 3 in 83 mm 0 6 in 15 mm 4 5 in 113 4 mm 1 2 in 30 mm 0 06 in 1 5 mm 2 13 in 54 mm 4 5 in 113 4 mm 3 3 in 83 mm 3 87 in 98 3 mm 1 14 in 29 1 mm 0 2 in 5 2 mm 0 39 in 10 mm 0 495 in 12 4 mm 0 315 in 7 55 mm ...

Страница 10: ... Area Network LAN Ethernet network using the supplied 8 conductor CAT5 Ethernet cable This connection is made directly to a network access device such as a router or through a wall jack that connects to a network access device Info The MagWeb is plugged directly into a wired Ethernet connection using the supplied Ethernet cable The Ethernet cable run is limited to 100 meters in total length The Et...

Страница 11: ... cables are correctly seated into the MagWeb device Red ON Green ON Red ON Green ON Power up sequence 1 second interval between each color The MagWeb device is performing a self test this occurs when first connected to power Green ON Normal operation the MagWeb device is correctly transmitting and receiving with network devices Green BLINKING Remote not connected or device is not able to communica...

Страница 12: ...ity and Link bi color LEDs within the MagWeb s Ethernet port Table 4 2 Functions of LEDs Below the Ethernet Port Link LED Activity LED Color Meaning Color Meaning Off No Link Off No Activity Amber 10 Mbps Amber Half Duplex Green 100 Mbps Green Full Duplex Note 1 Data transfers between Magnum s servers and the MagWeb system can only transmit in one direction at a time not simultaneously Note 2 Data...

Страница 13: ...or LEDs Link Activity Ethernet RJ11 Jack To Inverter RJ11 Jack To Remote SN MW50000 PN ME MW E Back View Top View Front View 2011 Magnum Energy Inc 9 Figure 4 1 MagWeb Wired Ethernet LED Diagram 4 0 Using LED Indicators to Determine Magweb s Status ...

Страница 14: ...evice Did you refer to Tables 4 1 and 4 2 to learn what the LED signals were communicating to you 5 2 Troubleshooting Questions and Answers What is this device on my network The MagWeb device allows remote monitoring of Magnum Energy invert ers and accessories Physically it is a small black box with an Ethernet cable and three LEDs How does it communicate When the first data is received from the M...

Страница 15: ...d off Verify that you can reboot your computer and then use a web browser to visit http data magnumenergy com If you cannot connect then the network connection will not work for the MagWeb The most likely problem is a network log in requirement or a firewall that does not allow outgoing data connections What if I still have questions Visit www magnumenergy com or call the Magnum Energy offices at ...

Страница 16: ...liant no lead used in manufacture Weight and Dimensions Shipping Weight 1 pound Dimensions l x w x h 4 5 x 2 2 x 1 2 114mm x 54mm x 30mm Kit Includes MagWeb Wired Ethernet Owner s Manual Remote cable 4 conductor 6 ft twisted pair telephone standard Mounting screws Ethernet cable 6 ft Requirements Access to an always on internet connection that is capable of sending approxi mately 2 5 megabytes of ...

Страница 17: ...by the price paid by the original purchas er Magnum Energy shall not be liable for any other losses or damages 4 Upon request from Magnum Energy the original purchaser must prove the product s original date of purchase by a dated bill of sale itemized receipt 5 The original purchaser shall return the product prepaid to Magnum Energy in Everett WA After the completion of service under this limited ...

Страница 18: ...g your product directly to Magnum Energy for repair you must return the unit in the original or equivalent shipping container receive a Return Materials Authorization RMA number from the factory prior to the return of the product to Magnum Energy for repair place RMA numbers clearly on the shipping container or on the packing slip When sending your product for service please ensure it is properly ...

Страница 19: ...Magnum Energy Inc 2211 West Casino Rd Everett WA 98204 Phone 425 353 8833 Fax 425 353 8390 Web www magnumenergy com PN 64 0055 Rev A ...

Отзывы: