57-642 ECLIPSE Model 705 Guided Wave Radar Transmitter for Hygienic Industries
Table of Contents
1.0 QuickStart Installation
1.1 Getting Started..........................................................4
1.1.1 Equipment and Tools..................................... 4
1.1.2 Configuration Information.............................5
1.2 QuickStart Mounting................................................5
1.2.1 Probe..............................................................5
1.2.2 Transmitter.....................................................6
1.3 QuickStart Wiring.................................................... 6
1.4 QuickStart Configuration......................................... 7
2.0 Complete Installation
2.1 Unpacking................................................................ 8
2.2 Electrostatic Discharge (ESD) Handling Procedure...8
2.3 Before You Begin.......................................................9
2.3.1 Site Preparation.............................................. 9
2.3.2 Equipment and Tools..................................... 9
2.3.3 Operational Considerations............................9
2.4 Mounting..................................................................9
2.4.1 Prior to Installing a Hygienic
Single Rod Probe..........................................10
2.4.1.1 To install a Model 7xF or Model 7xH
Single Hygienic Probe........................... 10
2.4.2 Installing the Transmitter............................. 11
2.4.2.1 Integral Mount......................................11
2.4.2.2 Remote Mount......................................11
2.5 Wiring.................................................................... 12
2.5.1 General Purpose or Non-Incendive
(CI I, Div 2)................................................. 12
2.5.2 Intrinsically Safe........................................... 13
2.5.3 Explosion Proof............................................13
2.6 Configuring the Transmitter....................................14
2.6.1 Operating Parameters................................... 14
2.6.2 Setting Up for Bench Configuration............ 14
2.6.3 Transmitter Display and Keypad.................. 15
2.6.4 Password Protection (Default = 0)................15
2.6.5 Model 705 Menu: Step-By-Step Procedure.. 16
2.6.5.1 Measurement Type: Level Only.............16
2.6.5.2 Measurement Type: Level and Volume.. 19
2.6.6 Offset Description........................................22
2.7 Configuration Using HART
®
..................................23
2.7.1 Connections................................................. 23
2.7.2 Display Menu...............................................23
2.7.3 HART Menu – Model 705 3.x.................... 24
2.7.4 HART Revision Table.................................. 25
3.0 Reference Information
3.1 Description............................................................. 25
3.2 Theory of Operation...............................................26
3.2.1 Micropower Impulse Radar.......................... 26
3.2.2 Time Domain Reflectometry (TDR)............26
3.2.3 Equivalent Time Sampling (ETS).................26
4.0 Initial Start-Up
4.1 Probe Location......................................................... 27
4.2 Probe Bends............................................................. 27
4.2.1 Shallow Bends................................................28
4.2.2 Field Bends.................................................... 28
4.2.3 Accommodating Non-Linearity..................... 29
4.3 Electronics Mounting...............................................30
4.4 Basic Start-Up.......................................................... 30
4.4.1 Probe Length................................................. 30
4.4.2 Blocking Distance and Damping .................. 30
4.4.3 Strapping Tables.............................................31
4.4.4 Tuning/Optimization..................................... 32
4.4.4.1 Dielectric Range/Sensitivity.....................32
4.4.4.2 PACT
ware
EchoCurve............................. 32
4.4.4.3 Blocking Distance................................... 32
4.4.4.4 Echo Curves in Dry and Filled States...... 32
4.4.4.5 Strapping Table Configuration................ 33
4.4.4.6 Additional Considerations....................... 33
5.0 Troubleshooting
5.1 Troubleshooting System Problems............................ 34
5.2 Status Messages........................................................ 35
5.3 Agency Approvals..................................................... 37
5.3.1 Agency Specifications (XP Installation).......... 37
5.3.2 Agency Specifications (IS Installation)........... 38
5.3.3 Agency Specifications (F
OUNDATION
fieldbus)... 39
6.0 Parts
6.1 Replacement Parts.................................................... 40
6.2 Recommended Spare Parts....................................... 40
7.0 Specifications
7.1 Functional................................................................ 41
7.1.1 O-Ring (Seal) Selection Chart....................... 41
7.2 Performance (Model 705)........................................ 42
7.3 Process Conditions................................................... 43
7.4 Probe Specifications................................................. 43
7.5 Physical.................................................................... 44
8.0 Model Numbers
8.1 Transmitter...............................................................45
8.2 Probe........................................................................46
9.0 Dry Calibration Procedure
9.1 Calibration Verification............................................ 47
9.1.1 Wet Calibration Verification of ECLIPSE...... 47
9.1.2 Dry Calibration Verification of ECLIPSE...... 47
9.1.3 Dry Calibration Verification Bench................47
9.2 Procedure to Verify Calibration of ECLIPSE........... 48
9.2.1 Initial Baseline Verification of ECLIPSE........ 48
9.2.2 Subsequent Calibration Verification............... 48
9.3 Sample Calibration Verification Document..............49
10.0 Hygienic Probe Rebuild Procedure..............................50
10.1 Model 7xH............................................................ 50
10.2 Model 7xF-E.......................................................... 51
Model 705 Configuration Data Sheet................................. 52
Strapping Table Data Sheet.................................................54
Appendix A: GWR – Emitted Energy................................. 55
Appendix B: Indexing Bent GWR Probes in Vessels............56
Appendix C: Segmented Probes...........................................58