52
Control unit MGC
Description of menus and parameters
6.4
"Service" menu
This menu is only intended for Magnetic's service and only accessible with a
password.
6.4.1
Gate HW
Use the "Gate HW" menu to select the target stop and set the 3 target
positions "Closed", "Left" and "Right".
The procedure corresponds to the "Service" tab of the "mSwing Connect"
programme.
1. Set the target stop using the "Homing direction" parameter.
2. Set target position "Closed" via the parameter "Align home position". The
set position corresponds to 0°.
3. Set target positions "Left" and "Right" via the parameters "Align pos. left"
and "Align pos. right".
Operational view > Main menu > Service > Gate HW
Parameter
Description
Align home position Set target position "Closed".
You start the process via the "Activated [ X ]" option. The motor is
disconnected from the power supply. Within 10 seconds you can move the
blocking element to the desired target position. The new target position is
accepted after 5 seconds.
Align posion left
Set target position "Left".
You start the process via the "Activated [ X ]" option. The motor is
disconnected from the power supply. Within 10 seconds you can move the
blocking element to the desired target position. The new target position is
accepted after 5 seconds.
Target position left
Check and adjust the angle of rotation of the blocking element.
Observe the position of the mechanical end stops. If necessary, the
mechanical end stops must be reset.
Setting range
›
0° … –120°
Factory setting
›
–90°
Align posion right
Set target position "Right".
You start the process via the "Activated [ X ]" option. The motor is
disconnected from the power supply. Within 10 seconds you can move the
blocking element to the desired target position. The new target position is
accepted after 5 seconds.