27
Control unit MGC
Description "mSwing Connect" programme
IMPORTANT!
After each change of the mechanical end stops you must check
the target positions and readjust them if necessary.
Procedure
1. Determine target stop if necessary.
2. Set target position "Closed (0°)". The set position corresponds to 0°.
3. Set target positions "Left" and "Right".
Setting target stop
1. Select the desired target stop for the "Homing target" parameter.
2. Click the "Write setting" button.
√
The changes are accepted.
√
Taught-in target positions "Closed (0°)", "Left" and "Right" are reset to
the factory setting.
Setting target positions
There are the 3 target positions "Closed (0°)", "Left" and "Right". First you have
to set the target position "Closed (0°)". Then you can set the two target
positions "Left" and "Right". During the setting process you must move the
blocking element to the desired target position.
The set target position "Closed (0°)" corresponds to 0°. The degrees for the
target positions "Left" and "Right" are determined by the "Closed (0°)"
position. The value for the target position "Left" is negative. The value for the
target position "Right" is positive.
IMPORTANT!
After you have clicked one of the 3 buttons, you have 10 seconds
to move the blocking element. The remaining time is displayed in
the "Align positions" area between the buttons.
Содержание MHTM FlowMotion
Страница 1: ...Description Swing door mSwing MHTM FlowMotion Control unit MGC Doc ID 5817 0031EN Version 00...
Страница 6: ...6 Control unit MGC...
Страница 77: ...77 Control unit MGC Index W Warning 12 Warning messages 47 63 Warning Notes Presentation 8 X X20 EN 55...
Страница 78: ...78 Control unit MGC...
Страница 79: ...79 Control unit MGC...