ReFlx 45 Collision Avoidance System Instruction Manual
September 2017
Page 9 of 17
2. Mechanical Installation
When mounting the sensor, no obstructions should be present between the sensor and the reflective
target. The sensor should be mounted so that the center of the sensor is lined up vertically with the center
of the reflective target. The mounting bracket provided allows for vertical adjustment by loosening the
screws through the curved slot. The sensor angle can be adjusted horizontally by loosening the screws
that secure the bracket. For fine adjustment of the sensor, it helps to view the target from a location within
1 ft. of the sensor, as it is difficult to see the red light reflected on the target if viewed from a distance
greater than 1 ft. in any direction.
Figure 3: Sensor and Target Installation