ReFlx 45 Collision Avoidance System Instruction Manual
September 2017
Page 7 of 17
approaching the sensing range/trip point, the sensor or reflector is dirty, or the sensor is slightly skewed.
Beyond the trip point, the yellow LEDs will turn off.
1.3 System Specifications
Specification
Specification Values and Information
Detection Range
approx. 3~45 ft.
Operating Voltage
12~240V AC/DC
Power Consumption
≤ 3.5 VA
Signal Output
Relay, Form C rated at 250 V AC/DC, 2 A
max
Switching Power Output DC: max. 50 W; AC: max. 500 VA
Response Time
≤ 20 ms
Operating Mode
Selection
DIP switch
Light Source
LED
Ambient Light Limit
80000 Lux
Ambient Temperature
-40°~140°F (-40°~60°C)
Storage Temperature
-40°~167°F (-40°~75°C)
Housing
Polycarbonate IP67
Terminal Block
Spring Loaded 16-20 AWG
Strain Relief
0.275~0.315 in. cable outside diameter
Standards and
Approvals
Low Voltage Directive 2006/95/EC
EMC Directive 2004
EN 60947-5-2: 2007
IEC 60947-5-2: 2007
cULus Listed to UL508, Class 2 Power
Source