1.6 Parameter Correspondence Table
P3 Series 2 and G+ Mini Differences in Parameter Settings
The list in Section 1.6 shows the parameter relations between the P3 Series 2 and the G+ Mini. It lists the parameters and
setting values necessary for P3 Series 2 replacement by a G+ Mini, but does not show the complete G+ Mini parameters and
extended parameter setting ranges. For details about new functions, parameters and parameter settings refer to the instruction
manual.
P3 Series 2
→
G+ Mini Parameter Correspondence for Drive Replacement
Drive
Parameter
Function
P3 Series 2
G+ Mini
Note
Param.
No.
Initial
Value
Set
Value
Param.
No.
Initial
Value
Set
Value
Motion Selection
n000
6
A01.03
1
P3 Series 2
G+ Mini
n000
→
0~4
A01.03
→
0
n000
→
5~9
A01.03
→
1
Speed Reference
Selection
A01.04
1
n000
→
0~4
A01.04
→
0~4
n000
→
5
n000
→
6
n000
→
7
n000
→
8
n000
→
9
A01.04
→
0
A01.04
→
1
A01.04
→
2
A01.04
→
3
A01.04
→
4
Initialize
A01.05
0
n000
→
0A
A01.05
→
2220
n000
→
20
A01.05
→
9990
Motor Rated Current
n001
1
A
E02.01
1
A
Access Level
n002
0
A01.01
1
P3 Series 2
G+ Mini
n002
→
0~1
A01.01
→
0
n002
→
2
A01.01
→
1
n002
→
9,A
A01.01
→
3
Frequency Reference 1
n003
6.00
B
B01.01
6.00
B
Frequency Reference 2
n004
30.00
B
B01.02
30.00
B
Frequency Reference 3
n005
60.00
B
B01.03
60.00
B
Frequency Reference 4
n006
0.00
B
B01.04
45.00
B
Frequency Reference 5
n007
60.00
B
B01.05
60.00
B
Acceleration Time 1
n008
5.0
B
B05.01
5.0
B
Deceleration Time 1
n009
3.0
B
B05.02
3.0
B
Special Functions
n010
0000
C01.01
0
B
P3 Series 2
G+ Mini
n010
→
xxx0
n010
→
xxx1
C01.01
→
0
C01.01
→
1
C01.03
0
n010
→
xx0x
n010
→
xx1x
C01.03
→
0
C01.03
→
1
C06.01
0
n010
→
x0xx
n010
→
x1xx
C06.01
→
0
C06.01
→
1
Acceleration Time 2
n011
2.5
B05.03
2.0
Deceleration Time 2
n012
1.5
B05.04
2.0
A
- Initial value depends on the drive model number.
B
- Value changes by X - press programming (A01.03)