Enrange Mini-MBT Instruction Manual
June 2015
Page 16 of 37
3.2.5 Transmitter Initialization (with Optional Graphic User Interface Screen)
Upon turning the transmitter on, the LCD screen turns on and the unit will perform a routine initialization.
During initialization, the Mini-MBT scans for any switches or motions that may be on during power up. If
any switches or motions are on, the failure will be shown on the display, and the Mini-MBT will power
itself down.
After a successful initialization, the Mini-MBT will enter the Normal Operation Mode and display the
normal operating screen. See Section 3.7 for more information on the Normal Operation Mode with
Optional Graphic User Interface.
NOTE: Holding the START toggle or button in the START position for more than 5 seconds will put the
device into Setup Mode. For normal use release the START toggle once the display turns on. See
Section 4.2 for more information on the Setup Mode.
3.2.6 Turning Off the Transmitter
The transmitter can be turned off by pressing the OFF-ON-START toggle switch down to the OFF
position. Once turned off, the MLC relay in the receiver is immediately opened.
NOTE: If the unit has a standard status LED, it will illuminate a solid red color during the transmitter’s
power down process. Once the power down process is complete, the transmitter will turn off and the
status LED will not be on.
NOTE: Depressing the Machine Stop switch will also turn the transmitter off and open the Machine Stop
relay in the receiver. See Section 3.3 for more information on the Machine Stop switch.
3.3 MACHINE STOP SWITCH (FOR EMERGENCY STOPPING ONLY)
When depressed, the Machine Stop relay in the receiver is immediately opened.
Under normal operating conditions, the Machine Stop switch must be in the raised position or the
transmitter and system will not operate.
NOTE: The Machine Stop Switch is to be used for emergency stopping only, not for normal system shut
down, unless it is specifically configured in that manner.
3.4 STATUS AND BATTERY LEDS
The standard Mini-MBT transmitter includes a status LED to let the operator know that the unit is
functioning and a battery LED to indicate when the battery level is low.
3.5 OPTIONAL GRAPHIC USER INTERFACE
The optional LCD screen provides visual information during the operation of the Mini-MBT transmitter. It
is used to change configuration settings, confirm commands being operated, provide two-way feedback,
and display transmitter diagnostic information such as battery life and signal strength.
The optional graphic user interface replaces the standard status and battery LEDs when ordered.