IMPULSE®•G+ & VG+ Series 3 to Series 4 Transition Guide August 2011
Page 37 of 54
Magnetek, Inc.
Product Transition Guide
IMPULSE
®
•G+ & VG+ Series 4
Torque Comp
Time
C8-01
(VG+ only)
Determined by
Drive
C8-01
(VG+ only)
1.0/1.5 sec
--
IFB OK Timer
C8-02
(VG+ only)
Determined by
Drive
C8-02
(VG+ only)
1.0/1.5 sec
--
Min Brk Rel Torq
C8-03
(VG+ only)
10%
C8-03
(VG+ only)
10%
--
Roll Back Timer
C8-04
0.3 sec
C8-04
(VG+ only)
0.3 sec
--
Roll Back Count
C8-05
(VG+ only)
800 pulses
C8-05
(VG+ only)
800 pulses
--
BE3/Alt Torq T
C8-06
(VG+ only)
0.30 sec
C8-06
(VG+ only)
0.30 sec
--
BE3 Det Count
C8-07
(VG+ only)
10 pulses
C8-07
(VG+ only)
10 pulses
--
Alt Rev Torq Lim
C8-08
(VG+ only)
25%
C8-08
(VG+ only)
25%
--
Zero Speed Level
C8-09
(VG+ only)
1 Hz
C8-09
(VG+ only)
1 Hz
--
Load Float Time
C8-10
(VG+ only)
10 sec
C8-10
(VG+ only)
10 sec
--
Brake Set Delay
C8-11
0.7 sec
C8-11
(VG+ only)
0.7 sec
--
BE6 Detect Timer
C8-12
(VG+ only)
5.0 sec
C8-12
(VG+ only)
5.0 sec
--
BE6 Max Count
C8-13
(VG+ only)
250 pulses
C8-13
(VG+ only)
250 pulses
--
Brake Hold Speed
C8-14
(VG+ only)
0.0%
C8-14
(VG+ only)
5.0 (OLV)
0.0 (FLV)
--
Load Float Ext. T
C8-15
(VG+ only)
10 sec
C8-15
(VG+ only)
10 sec
Init Brk Rel Trq
C8-16
(VG+ only)
100%
--
--
--
BE6 Up Speed
C8-17
(VG+ only)
6.00 Hz
C8-18
(VG+ only)
6.00 Hz
--
Brake Test Torq
C8-19
(VG+ only)
125%
C8-24
(VG+ only)
125%
--
Brake Test Speed
C8-20
(VG+ only)
6 Hz
C8-20
(VG+ only)
6 Hz
--
Height Measure
C8-21
(VG+ only)
10000 pulses
C3-13
(VG+ only)
250
--
Hook Height
Home
C8-24
(VG+ only)
0
C3-14
(VG+ only)
0
0: Home = UL2
0: Home = UL2
1: Home = LL2
1: Home = LL2
2: Home = Hook
Height Home
2: Home MFDI
Upper
--
3: Home MFDI
Lower
4: Home = UL3
4: Home = UL3
Parameter
Name
Series 3
Series 4
Comments
No.
Default
No.
Default
Series 3
Series 4