Product Transition Guide
IMPULSE
®
•G+ & VG+ Series 4
IMPULSE®•G+ & VG+ Series 3 to Series 4 Transition Guide August 2011
Page 36 of 54
Magnetek, Inc.
Min Torque Ref
C5-03
60%
C5-03
60%
--
Look Speed I
C5-04
6 Hz
--
--
--
Look Speed 2
C5-07
20 Hz
--
--
--
I/T Ref for LS 2
C5-08
160%
--
--
--
Look Speed 3
C5-09
40 Hz
--
--
--
I/T Ref for LS 3
C5-10
160%
--
--
--
I Ref for > LS 3
C5-11
160%
--
--
--
LC Holding Time
C5-12
1.00 sec
--
--
--
LC Testing Time
C5-13
0.25 sec
C5-13
0.25 Hz
--
LC Fault Speed
C5-14
6 Hz
C5-14
6 Hz
--
Swift Lift 0/1
(G+S3)
Ultra Lift 0/1
(VG+S3)
C6-01
0
C6-01
0
0: Disabled
0: Disabled
1: Enabled
Automatic
1: Enabled Auto
2: Enabled by MFI
= 13
2: Enabled by
MFDI
--
3: Enabled
Adaptive
--
4: Adaptive by
MFDI
Swift Lift ForSpd
(G+S3)
Ultra Lift ForSpd
(VG+S3)
C6-02
60 Hz
C6-02
60 Hz
--
Swift Lift RevSpd
(G+S3)
Ultra Lift RevSpd
(VG+S3)
C6-03
60 Hz
C6-03
60 Hz
--
SL Fwd Torque
(G+S3)
UL Fwd Torque
(VG+S3)
C6-04
50%
C6-04
50%
--
SL Rev Torque
(G+S3)
UL Rev Torque
(VG+S3)
C6-05
30%
C6-05
30%
--
UL Enabling Spd
C6-06
59 Hz
C6-06
59 Hz
--
UL Delay Time
C6-07
2.0 sec
C6-07
2.0 sec
--
SFS Acc Gain
C6-08
1.0
C6-08
1.0
--
Normal OS Level
C6-09
(VG+ only)
60 Hz
--
--
--
Torq Limit Fwd
C7-01
150%
C7-01
150%
--
Torq Limit Rev
C7-02
150%
C7-02
150%
--
Torq Lmt Fwd Rgn
C7-03
180%
C7-03
180%
--
Torq Limit Rev
Rgn
C7-04
180%
C7-04
180%
--
Torq Limit Gain
C7-07
1.25
--
--
--
Trav Trq Limiter
C7-08
(VG+ only)
0
C7-10
0
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Limiter Freq
C7-09
(VG+ only)
2.0
C7-11
2.0
--
Parameter
Name
Series 3
Series 4
Comments
No.
Default
No.
Default
Series 3
Series 4