15
1.6
START-UP WITHOUT DIGITAL OPERATOR
(2-Wire control; see Figure 1-5) (constant
no-01
set to 0000
[factory setting] )
ACTION
Freq. Ref. set at
zero; FWD RUN
and REV RUN
inputs open.
Apply Power.
Increase Freq.
Ref. input to
maximum.
Status Plate
DS1 DS2
(GREEN) ( RED )
BLINKING
Off
LIT
Off
LIT
Off
LIT
Off
(during decel)
BLINKING
Off
(when stopped)
DESCRIPTION
Ready for operation.
Close FWD RUN
or REV RUN
input; increase
Freq. Ref. until
motor rotates.
Open FWD RUN
or REV RUN
input.
Check that motor is rotating in
the correct direction. See Note 1.
Motor speed decreases under
GPD 333 control, at programmed
decel rate (constant
no–10
; fac-
tory setting = 10.0 seconds decel
time from 60Hz to 1.5Hz). Motor
then remains stopped.
GPD 333 output increases at pro-
grammed accel rate (constant
no–09
; factory setting = 10.0 sec-
onds accel time from 1.5Hz to
60Hz) to level commanded by fre-
quency reference input. Motor
speed increases accordingly.
NOTES:
1.
If motor is not rotating in proper direction, stop motor and
turn off power to the GPD 333. Switch motor connections T1
(U) & T2 (V) at the GPD 333 to change direction.
efesotomasyon.com - Yaskawa ac drive,servo motor
Содержание GPD 333
Страница 1: ...Magne Tek GPD 333 Technical Manual efesotomasyon com Yaskawa ac drive servo motor ...
Страница 3: ...efesotomasyon com Yaskawa ac drive servo motor ...
Страница 6: ...efesotomasyon com Yaskawa ac drive servo motor ...
Страница 14: ...efesotomasyon com Yaskawa ac drive servo motor ...
Страница 15: ...efesotomasyon com Yaskawa ac drive servo motor ...
Страница 16: ...efesotomasyon com Yaskawa ac drive servo motor ...
Страница 17: ...efesotomasyon com Yaskawa ac drive servo motor ...
Страница 61: ...48 This page intentionally left blank efesotomasyon com Yaskawa ac drive servo motor ...
Страница 76: ...62 This page intentionally left blank efesotomasyon com Yaskawa ac drive servo motor ...
Страница 78: ...efesotomasyon com Yaskawa ac drive servo motor ...