43
Detection
160%
time
OUTPUT
100%
(Constant
CURRENT
no-42
)
0
100%
Coast
MOTOR
stop
SPEED
0
RUN
SIGNAL
STOP
SIGNAL
OPEN COLLECTOR
OUTPUT
(OVERTORQUE
DETECTION)
TERM. 14 & 7
(Constant
no-38
set to 04)
Overtorque Detection Timing Diagram
EXAMPLE:
Constant
no-38
= 04 (See paragraph 3.18)
Constant
no-40
= 0101 ; Overtorque enabled, only
at set frequency, coast to stop
Constant
no-41
= 160 ( % )
Constant
no-42
= 1.0 ( s )