Flex Mini System Instruction Manual
June 2015
Page 18 of 25
7
1
4
2 3
5 6
8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
2.2 RECEIVER
2.2.1 Dipswitch Settings
Top position 1
Bottom position 0
Dipswitch #1 (right):
Position
Dip 1
Dip 2
Dip 3
Dip 4
Dip 5
Dip 6
Dip 7
Dip 8
Set to 0
PB1
Normal
PB2
Normal
PB3
Normal
PB4
Normal
PB5
Normal
PB6
Normal
PB7
Normal
PB8
Normal
Set to 1
PB1
Toggled
PB2
Toggled
PB3
Toggled
PB4
Toggled
PB5
Toggled
PB6
Toggled
PB7
Toggled
PB8
Toggled
Toggled functions maintain contact when transmitter power is turned off (keypad type 2) or Stop button is pressed (keypad type 3).
Dipswitch #2 (left):
Position
Dip 1
Dip 2
Dip 3
Dip 4
Dip 5
Dip 6
Dip 7
Dip 8
Set to 1
PB1&2
On & Off
PB3&4
On & Off
PB5&6
On & Off
PB7&8
On & Off
PB1&2
Interlocked
PB3&4
Interlocked
PB5&6
Interlocked
PB7&8
Interlocked
Set to 0: According to dip-switch #1 setting.
Dip 5~8 set to 1: Button pair interlocked. When set to interlocked pair you must reconfigure dip-switch #1 below.
On & Off function turns to “Off” when transmitter power is turned off (keypad type 2) or Stop button is pressed (keypad type 3).
Dipswitch #1 (right) - Normal and Toggled Interlocked Settings:
Position
Dip 1&2
Dip 3&4
Dip 5&6
Dip 7&8
Set to 00
PB1&2 Normal/Normal
Interlocked
PB3&4 Normal/Normal
Interlocked
PB5&6 Normal/Normal
Interlocked
PB7&8 Normal/Normal
Interlocked
Set to 01
PB1&2 Toggled/Toggled
Interlocked
PB3&4 Toggled/Toggled
Interlocked
PB5&6 Toggled/Toggled
Interlocked
PB7&8 Toggled/Toggled
Interlocked
Dipswitch #2 (left) - ID Function Settings (keypad type 3):
Position Function Position Function
Set to 0001001
K2 output relay closes when
PB7 & PB8 is pressed.
Set to 0001101
K2 output relay closes when
PB3 & PB4 or PB7 & PB8 is pressed.
Set to 0001010
K2 output relay closes when
PB5 & PB6 is pressed.
Set to 0001110
K2 output relay closes when
PB3 ~ PB6 is pressed.
Set to 0001011
K2 output relay closes when
PB5 ~ PB8 is pressed.
Set to 0001111
K2 output relay closes when
PB3 ~ PB8 is pressed.
Set to 0001100
K2 output relay closes when
PB3 & PB4 is pressed.
When a button pair is set to the ID function the corresponding button setting on dipswitch #1 must set to “0”.
When set to ID function the START/AUX function on keypad type 3 is disabled (auxiliary function replaced by ID function).