Flex 12EX2 Standard, AB and Tandem Instruction Manual
November 2017
Page 41 of 56
4.2.7
Other Function Output Relays Settings
Listed below are other types of functions that can be outputted through the three
Function output relays (K25, K26 and K30) via the infrared IR programmer unit.
Contact Magnetek field service for more details.
LV
→
Function relay closes when receiver voltage is low.
ID
→
Function relay works simultaneously with all motion
commands.
NORMAL
→
START fu AUX with normal
momentary output.
TOGGLE
→
START fu AUX with toggled/latching
output.
TOG&E
→
START fu AUX with toggled/latching
output. The relay opens when STOP button is pressed
down and transmitter power is off.
S/P
→
Function relay closes when START command is executed and opens only when
transmitter power is turned off.
EXT
→
Function relay works simultaneously with the receiver MAIN relays.
TDM A+B
→
Function relay closes when selector switch is rotated to the A+B position
and opens when rotate to A or B positions (tandem monitoring output).
HORN
→
Function relay closes for up to 3 seconds when START command is executed
at transmitter power on and then becomes a normal momentary output thereafter.
G SENSOR
→
Function relay closes when Zero-G sensor is triggered (receiver MAIN
relays deactivated) and opens when receiver MAIN relays are reactivated.
4.2.8
Receiver Select Setup (RS Systems Only)
The receiver select systems use the small Flex EX2 receiver. For wiring, refer to the
wiring diagram on the front of the receiver or the Flex 4EX2 manual.
TYPE D: A/B Receiver Select with Flex 12 Transmitter
-12 Button Transmitter (bottom two buttons for A/B Select)
-6 Receivers (A-1, A-2, A-3, B-1, B-2 and B-3)
TYPE E: A, B, C, D Receiver Select with Bridge Receiver
-12 Button Transmitter (bottom four buttons for A, B, C, D Select)
-5 Receivers (A, B, C, D and Bridge)