Flex 12EX2 Standard, AB and Tandem Instruction Manual
November 2017
Page 19 of 56
B.
Receiver-to-Transmitter Pairing:
JP8 Open Method:
After the transmitter enters the Remote Pairing mode, output
receiver data by pressing and holding the PAIRING button located on the receiver
cover and receive data by pressing and holding PB3 on the transmitter, both at the
same time. When the transmitter Status LED turns to solid green while both
pushbuttons are still pressed down the pairing is completed.
JP8 Short Method (press Pairing button not required):
After the transmitter
enters the Remote Pairing mode, press and hold PB3 on the transmitter until the
Status LED turns to solid green, indicating the pairing is completed. Make sure the
transmitter and receiver are within 10 meters from one another and that no other
active receivers are nearby during the pairing process. During pairing process the
receiver MAIN relays must be deactivated (relay open). For tandem systems make
sure the receiver is not locked to any of its existing transmitters.
4.1.4
I-Chip
When an I-Chip is inserted into the Flex EX2 transmitter it becomes backwards
compatible with a Flex EX (GEN 1) receiver. Refer to the appropriate Flex EX
(GEN 1) manual for information on configuring the I-Chip or contact Magnetek field
service.
NOTE:
A Flex EX (GEN 1) transmitter will NOT work with a Flex EX2 receiver.
→
→
Set JP8 to “Open” Output data – receiver
Receiving data – transmitter
(press and hold the Pairing button) (press and hold PB3)