Flex 12EX2 Standard, AB and Tandem Instruction Manual
November 2017
Page 38 of 56
Example #1: Left button (set to function code A) / right button (set to function code B)
→
1 000 001
Example #2: Left button (set to function code C) / right button (set to function code D)
→
1 011 100
Function
Code
Dip
Position
#1
Dip Position
#2 - #4 (left button) and
#5 - #7 (right button)
Function Description
A
1
000
Normal momentary contact
B
1
001
Toggled/latching contact
(type A)
C
1
011
Toggled/latching contact
(type B)
Output relay disconnects
when STOP button is
pressed or transmitter
power is off
D
1
100
Start function
For added safety, first rotate
and hold the power switch
key at the START position
and then press the intended
pushbutton to activate the
output relay
E
1
110
Pitch & Catch (type A)
F
1
101
Pitch & Catch (type B)
Receiver MAIN relays
maintain closure
during switchovers
G
1
111
2 steps with Closed/Closed
relay action