Regenerative
Power
Module
-
September
2010
144-45117-R3
Page 7 of 20
•
LED Fault and Status Indicators
LED status indicators provide the following indications:
COLOR MARKING
DESCRIPTION
GREEN POWER
Indicates
that
the brake chopper power supply is
present
GREEN INTERLOCK
Indicates that the external contact is closed when the
interlock is enabled or that the interlock is in the
disabled position
GREEN READY
Indicates that no fault condition exists and that the
external interlock is not open
AMBER ACTIVE
Indicates
that
the brake chopper is conducting
AMBER RESET
Indicates that the reset circuit is activated
RED
OVERTEMP
Indicates that the heat sink temperature has reached
95
°
C and the module has shut down to protect the
transistor.
RED
IGBT FAULT
Indicates that the module is shut down on short
circuit IGBT detection
•
TEST Switch
The TEST switch simulates a DC bus voltage increase; this input is used to set the turn on voltage
and verify transistor and resistor functionality.