According to IEC 60974-9 section 5.2
Before installing arc welding equipment the user shall make an assessment of potential electromagnetic
problems in the surrounding area. The following shall be taken into account:
a) other supply cables, control cables, signalling and telephone cables, above, below and adjacent to the
arc welding equipment;
b) radio and television transmitters and receivers;
c) computer and other control equipment;
d) safety critical equipment, for example guarding of industrial equipment;
e) the health of the people around, for example the use of pacemakers and hearing aids;
f) equipment used for calibration or measurement;
g) the immunity of other equipment in the environment. The user shall ensure that other equipment being
used in the environment is compatible. This may require additional protection measures;
h) the time of day that welding or other activities are to be carried out.
İn addition considering the area, There may be need to consider setting up at machine for soluing the
distortion.
If it is necessary, there may used appropriate measurements and preventative precautions,
EVALUATION FOR ELECTROMAGNETIC COMPATIBILITY OF WORKING AREA
METHODS OF REDUCTION INTERFERENCE
Ÿ
As recommended in the device and be connected to the mains by a qualified person. If interference is
applicable additional measures such as filtering of network. Fixed mounted power supply cable of arc
welding equipment should be shielded in metal pipes or equivalent structures. Storage cable must be
electrically continuous along its length. Metal pipes and / or the display must be connected with the power
supply casing and ensured a good electrical contact between these two structures.
Ÿ
The recommended routine maintenance must be carried out. The device in use, all doors closed bodywork
and / or should be locked. Any change other than the default settings on the device without the written
approval of the Central Service, modifications strictly prohibited. Otherwise every possible situation that
can occur is ultimately responsible for the user.
Ÿ
Welding cables should be kept as short as possible, and the floor of the work area so that they must go side
by side. Welding cable should be wrapped in any way.
Ÿ
Care should be taken to reduce emissions surrounding the connection of all metal objects. However, metal
objects connected to the workpiece, the operator touching the metal object and the electrode at the same
time it will increase the risk of the possibility of distortion. The operator must be isolated from all the
interconnected metal object.
Ÿ
Workpiece size and position due to electrical safety purposes or soil where binding (e.g., ship hulls or steel
construction) is a connection to be made between the ground and the work piece may reduce emissions in
some cases. Workpiece grounded the user or the environment of other electrical equipment should be
noted that the injury may lead to malfunction. Where necessary land connection with the workpiece can be
done through direct contact, but can not be allowed to directly link connection in accordance with local
regulations in some countries can be created using elements of suitable capacity.
Ÿ
Shielding and protection of cables and other equipment in the work area can provide the prevention of
corruption problems. Shielding the source of all assessed for specific applications.