EN
www.magmaweld.com
28
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
SMART SERIES / SMART SERİSİ
3.4 Arc Length Adjustment (ArC)
When you press and hold the adjustment knob
(9)
for 3 seconds, the arc length function will be active. The factory setting is 0.0. You can change the
arc length adjustment in the range of + 7 / -7 by turning the same knob to the right or left. As it goes t7, the wire approaches the nozzle, the
arc length increases. As it goes towards -7, the wire approaches the welding metal and the arc length decreases. After the desired setting is made, the
setting is exited by pressing the same knob.
3.5 MIG Curve
SMART SERIES Parametre
Value Range
Factory Setting
2- Position MIG
4- Position MIG
Pre-Gas
0,0 - 9,9 sec
0,1 sec
Wire Type
Steel, AlMg, FCW, AlSi, FCW-M, CuSi, CrNi, CuAl
Arc Off Time
0,0 - 9,9 sec
0,0 sec
Trigger
Method / 2 / 4
2
Burn Back
25 - 0 - 25
0 step
Crater
Active / Passive
Passive
Thickness
0,6 - 20,0 mm
1,0 mm
Post Gas
0,0 - 9,9 sec
0,1 sec
Wire Diameter
0,6 - 2,4 mm
1,0 mm
Method
MIG/MAG - MMA -
LIFT TIG
MIG / MAG
Arc On Time
0,2 - 9,9 sec
0,2 sec
Mode
Synergic / Smart / Classic
Gas Type
CO2, Ar/5-10 CO2, Ar/15-25 CO2, Ar/2.5 C02, Ar/10-15 CO2, Argon
Set Voltage
Set Wire
Voltage 0 - 25
Crater Open
Pre Gas
Wire 0 - 25
Wire 0 - 25
Crater Closed
Crater Open
Crater Closed
Set Voltage
Set Wire
Voltage 0 - 25
Pre-Gas
Pre-Gas
Pre-Gas
Pre-Gas
Spot
Slow Release
On
Slow Release
Off
Slow Release
On
Slow Release
Off
Crater
Crater
Pnt Mode
On
Pnt Mode
Off
Burn Back
Post Gas
Burn Back
Burn Back
Burn Back
Post Gas
Post Gas
Post Gas
Post Gas
Operation